National Dam Inspection Program. Hosensack Number 4 Dam (NDI ID PA 00786, PA DER 39-4), Delaware River Basin, Indian Creek, Pennsylvania. Phase I Inspection Report,
Peter C. Johnson
Abstract
Peter C. Johnson
Abstract
Hosensack No. 4 Dam is a masonry structure with an upstream embankment. The dam has a maximum height of about 32 feet and a length of 310 feet. A 175-foot long overflow spillway is located about 100 feet from the right abutment near the center of the structure and is capped with concrete in the masonry portion. A 24-inch diameter reinforced concrete drain pipe is located in the non-overflow portion of the dam about 3.5 feet left of the spillway section. Discharge through the pipe is controlled with stop planks in a drainage tower approximately 15 feet downstream from the intake. A review of the results of the hydrologic and hydraulic analyses indicates that the spillway is able to pass the Spillway Design Flood (SDF) without the dam being overtopped; therefore, the spillway is considered 'Adequate'. Based on visual observation and a review of the information obtained from the Pennsylvania Department of Environmental Resources, Hosensack No. 4 Dam appears to be in poor condition.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Hosensack No. 4 Dam is a masonry structure with an upstream embankment. The dam has a maximum height of about 32 feet and a length of 310 feet. A 175-foot long overflow spillway is located about 100 feet from the right abutment near the center of the structure and is capped with concrete in the masonry portion. A 24-inch diameter reinforced concrete drain pipe is located in the non-overflow portion of the dam about 3.5 feet left of the spillway section. Discharge through the pipe is controlled with stop planks in a drainage tower approximately 15 feet downstream from the intake. A review of the results of the hydrologic and hydraulic analyses indicates that the spillway is able to pass the Spillway Design Flood (SDF) without the dam being overtopped; therefore, the spillway is considered 'Adequate'. Based on visual observation and a review of the information obtained from the Pennsylvania Department of Environmental Resources, Hosensack No. 4 Dam appears to be in poor condition.
Key concepts: Spillway, Abutment, Geotechnical engineering, Flood myth, Embankment dam, Geology, Canyon, Hydrology (agriculture)