2015•Australian Journal of Electrical & Electronics EngineeringRequires access

A novel method for removing the decaying DC component in digital relays

Seyed Hassan Ashrafi Niaki, Zeynab Zandi

Open publisher page 0 citations

Abstract

One of the major duties of digital relaying is the accurate estimation of fundamental frequency and its phasor. Digital relays usually use discrete Fourier transform to estimate the fundamental frequency harmonic, but decaying DC component is a great challenge to achieve this goal when a fault occurs. This paper presents a new integral-based method to remove the DC offset from current signal. The proposed method uses only half of the sampled data per cycle plus one sample to appraise time constant and magnitude of the DC offset. Then, by subtracting value of the decaying DC component at each sample, DC-removed signal can be achieved. The performance of the proposed technique is evaluated by computer-based signals and signals generated by EMTP. The results illustrate appropriate operation of the suggested algorithm in removing the decaying DC component.

About this research paper

What this paper is about

One of the major duties of digital relaying is the accurate estimation of fundamental frequency and its phasor. Digital relays usually use discrete Fourier transform to estimate the fundamental frequency harmonic, but decaying DC component is a great challenge to achieve this goal when a fault occurs. This paper presents a new integral-based method to remove the DC offset from current signal. The proposed method uses only half of the sampled data per cycle plus one sample to appraise time constant and magnitude of the DC offset. Then, by subtracting value of the decaying DC component at each sample, DC-removed signal can be achieved. The performance of the proposed technique is evaluated by computer-based signals and signals generated by EMTP. The results illustrate appropriate operation of the suggested algorithm in removing the decaying DC component.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

One of the major duties of digital relaying is the accurate estimation of fundamental frequency and its phasor. Digital relays usually use discrete Fourier transform to estimate the fundamental frequency harmonic, but decaying DC component is a great challenge to achieve this goal when a fault occurs. This paper presents a new integral-based method to remove the DC offset from current signal. The proposed method uses only half of the sampled data per cycle plus one sample to appraise time constant and magnitude of the DC offset. Then, by subtracting value of the decaying DC component at each sample, DC-removed signal can be achieved. The performance of the proposed technique is evaluated by computer-based signals and signals generated by EMTP. The results illustrate appropriate operation of the suggested algorithm in removing the decaying DC component.

Key concepts: DC bias, Phasor, Computer science, Offset (computer science), Fundamental frequency, Emtp, Harmonic, Component (thermodynamics)

Related papers

Back to paper searchBrowse research topicsOriginal source
A novel method for removing the decaying DC component in digital relays — Research Paper | ScholarLens