2015Physiological ReportsOpen access

Heat acclimation and thirst in rats

Christopher C. Barney, Elizabeth M. Schanhals, Justin L. Grobe, Bradley T. Andresen, Michael D. Traver

Open full text 8 citations

Abstract

The effects of heat acclimation on water intake and urine output responses to thermal dehydration and other thirst stimuli were studied in male Sprague-Dawley rats. Rats were heat acclimated by continuous exposure to a 34°C environment for at least 6 weeks. Thermal dehydration-induced thirst was brought about by exposing the heat-acclimated rats and control rats housed at 24°C to a 37.5°C environment for 4 h without access to food or water. Heat acclimation reduced evaporative and urinary water losses and the increases in plasma sodium and osmolality during thermal dehydration, which led to a reduction in thermal dehydration-induced thirst. Heat acclimation reduced the rate of rehydration following thermal dehydration but did not alter the final rehydration level, indicating that heat acclimation does not alter the primary control of thermal dehydration-induced thirst. Heat acclimation did not alter water intake or urine output following administration of hypertonic saline, which selectively stimulates intracellular thirst, but led to greater water intake following administration of angiotensin II, which plays an important role in extracellular/volemic thirst, and following water deprivation, which activates both thirst pathways. Cardiovascular responses to angiotensin II were not altered by heat acclimation. Heat acclimation thus reduces water loss during heat exposure in rats, but does not have major effects on thermal dehydration-induced or extracellular thirst but does appear to alter volemic thirst.

Open-access reader

About this research paper

What this paper is about

The effects of heat acclimation on water intake and urine output responses to thermal dehydration and other thirst stimuli were studied in male Sprague-Dawley rats. Rats were heat acclimated by continuous exposure to a 34°C environment for at least 6 weeks. Thermal dehydration-induced thirst was brought about by exposing the heat-acclimated rats and control rats housed at 24°C to a 37.5°C environment for 4 h without access to food or water. Heat acclimation reduced evaporative and urinary water losses and the increases in plasma sodium and osmolality during thermal dehydration, which led to a reduction in thermal dehydration-induced thirst. Heat acclimation reduced the rate of rehydration following thermal dehydration but did not alter the final rehydration level, indicating that heat acclimation does not alter the primary control of thermal dehydration-induced thirst. Heat acclimation did not alter water intake or urine output following administration of hypertonic saline, which selectively stimulates intracellular thirst, but led to greater water intake following administration of angiotensin II, which plays an important role in extracellular/volemic thirst, and following water deprivation, which activates both thirst pathways. Cardiovascular responses to angiotensin II were not altered by heat acclimation. Heat acclimation thus reduces water loss during heat exposure in rats, but does not have major effects on thermal dehydration-induced or extracellular thirst but does appear to alter volemic thirst.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effects of heat acclimation on water intake and urine output responses to thermal dehydration and other thirst stimuli were studied in male Sprague-Dawley rats. Rats were heat acclimated by continuous exposure to a 34°C environment for at least 6 weeks. Thermal dehydration-induced thirst was brought about by exposing the heat-acclimated rats and control rats housed at 24°C to a 37.5°C environment for 4 h without access to food or water. Heat acclimation reduced evaporative and urinary water losses and the increases in plasma sodium and osmolality during thermal dehydration, which led to a reduction in thermal dehydration-induced thirst. Heat acclimation reduced the rate of rehydration following thermal dehydration but did not alter the final rehydration level, indicating that heat acclimation does not alter the primary control of thermal dehydration-induced thirst. Heat acclimation did not alter water intake or urine output following administration of hypertonic saline, which selectively stimulates intracellular thirst, but led to greater water intake following administration of angiotensin II, which plays an important role in extracellular/volemic thirst, and following water deprivation, which activates both thirst pathways. Cardiovascular responses to angiotensin II were not altered by heat acclimation. Heat acclimation thus reduces water loss during heat exposure in rats, but does not have major effects on thermal dehydration-induced or extracellular thirst but does appear to alter volemic thirst.

Key concepts: Thirst, Dehydration, Acclimatization, Hypertonic saline, Chemistry, Internal medicine, Endocrinology, Thermoregulation

Related papers

Back to paper searchBrowse research topicsOriginal source
Heat acclimation and thirst in rats — Research Paper | ScholarLens