1999International Journal of AudiologyRequires access

A Comparison of Extratympanic versus Transtympanic Recordings in Electrocochleography

Yoshihiro Noguchi, Hiroaki Nishida, Atsushi Komatsuzaki

Open publisher page 34 citations

Abstract

Detection thresholds, amplitudes and input output curves of cochlear microphonics (CMs), and action potentials (APs) determined by extratympanic electrocochleography (ET ECochG) were compared with those determined by transtympanic (TT) ECochG in the same ears. Two groups were studied: 12 ears in 9 volunteers with normal hearing, and 6 ears in 6 subjects with sensorineural hearing loss. Short tone bursts with frequencies of 0.5, 1, 2 and 4 kHz were used as acoustic stimuli to evoke CMs, and a click was presented to measure the APs. In both groups, although the two approaches produced large differences in amplitudes, nearly identical values were obtained for the CM and AP detection thresholds. The CM and AP input-output curves obtained from mean amplitudes at each intensity in normally-hearing ears had similar slopes with the two approaches. These findings demonstrate the clinical usefulness of ET ECochG.

About this research paper

What this paper is about

Detection thresholds, amplitudes and input output curves of cochlear microphonics (CMs), and action potentials (APs) determined by extratympanic electrocochleography (ET ECochG) were compared with those determined by transtympanic (TT) ECochG in the same ears. Two groups were studied: 12 ears in 9 volunteers with normal hearing, and 6 ears in 6 subjects with sensorineural hearing loss. Short tone bursts with frequencies of 0.5, 1, 2 and 4 kHz were used as acoustic stimuli to evoke CMs, and a click was presented to measure the APs. In both groups, although the two approaches produced large differences in amplitudes, nearly identical values were obtained for the CM and AP detection thresholds. The CM and AP input-output curves obtained from mean amplitudes at each intensity in normally-hearing ears had similar slopes with the two approaches. These findings demonstrate the clinical usefulness of ET ECochG.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Detection thresholds, amplitudes and input output curves of cochlear microphonics (CMs), and action potentials (APs) determined by extratympanic electrocochleography (ET ECochG) were compared with those determined by transtympanic (TT) ECochG in the same ears. Two groups were studied: 12 ears in 9 volunteers with normal hearing, and 6 ears in 6 subjects with sensorineural hearing loss. Short tone bursts with frequencies of 0.5, 1, 2 and 4 kHz were used as acoustic stimuli to evoke CMs, and a click was presented to measure the APs. In both groups, although the two approaches produced large differences in amplitudes, nearly identical values were obtained for the CM and AP detection thresholds. The CM and AP input-output curves obtained from mean amplitudes at each intensity in normally-hearing ears had similar slopes with the two approaches. These findings demonstrate the clinical usefulness of ET ECochG.

Key concepts: Electrocochleography, Audiology, Microphonics, Tone burst, Medicine, Audiometry, Sensorineural hearing loss, Cochlea

Related papers

Back to paper searchBrowse research topicsOriginal source
A Comparison of Extratympanic versus Transtympanic Recordings in Electrocochleography — Research Paper | ScholarLens