2014설비공학논문집Requires access

사무소 건축물에서 다이나믹 윈도우의 에너지 성능 분석

박률, 박경순

Open publisher page 0 citations

Abstract

Low solar gain glazing should be applied on windows in order to reduce the solar radiation load. In a country where a cooling and a heating load coexist throughout the year, such as in Korea, a high solar gain glazing is need to reduce the heating load, but a low solar gain glazing should be applied to reduce the cooling load. Recently, dynamic windows have been developed for which the solar shading performance switches according to the amount of solar radiation flowing into the indoor space through the glazing, and these have been used in building to solve such problems. The purpose of this research is to analyze the energy performance of the electrochromic glazing for dynamic windows that has been extensively commercialized for office buildings in Incheon and Ulsan through an energy simulation implemented in the eQUEST program

About this research paper

What this paper is about

Low solar gain glazing should be applied on windows in order to reduce the solar radiation load. In a country where a cooling and a heating load coexist throughout the year, such as in Korea, a high solar gain glazing is need to reduce the heating load, but a low solar gain glazing should be applied to reduce the cooling load. Recently, dynamic windows have been developed for which the solar shading performance switches according to the amount of solar radiation flowing into the indoor space through the glazing, and these have been used in building to solve such problems. The purpose of this research is to analyze the energy performance of the electrochromic glazing for dynamic windows that has been extensively commercialized for office buildings in Incheon and Ulsan through an energy simulation implemented in the eQUEST program

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Low solar gain glazing should be applied on windows in order to reduce the solar radiation load. In a country where a cooling and a heating load coexist throughout the year, such as in Korea, a high solar gain glazing is need to reduce the heating load, but a low solar gain glazing should be applied to reduce the cooling load. Recently, dynamic windows have been developed for which the solar shading performance switches according to the amount of solar radiation flowing into the indoor space through the glazing, and these have been used in building to solve such problems. The purpose of this research is to analyze the energy performance of the electrochromic glazing for dynamic windows that has been extensively commercialized for office buildings in Incheon and Ulsan through an energy simulation implemented in the eQUEST program

Key concepts: Glazing, Solar gain, Cooling load, Building energy simulation, Passive solar building design, Solar energy, Environmental science, Architectural engineering