1971Chemistry & IndustryRequires access

PARTICLE SIZE ANALYSIS WITH MICRO SIEVES USING ULTRASONIC VIBRATIONS

J.W. Mullin

Open publisher page 0 citations

Abstract

A SIMPLE AND RELIABLE TECHNIQUE IS DESCRIBED WHICH AVOIDS DAMAGE TO THE MICROMESHES INVOLVED IN SIEVING MATERIAL BELOW 20 MICROMETRES USING ULTRASONIC VIBRATIONS. THE SIEVE IS DRIED TO CONSTANT WEIGHT IN AN OVEN BELOW 70 DEGREES C AND COOLED IN A DESICCATOR. THE SIEVE AND ABOUT 1 GRAM OF THE SAMPLE ARE WEIGHED TO A PRECISION OF + OR - 0.2MG. THE SIEVE IS THEN FITTED LOOSELY INTO A METAL RETAINER PLATE CONTAINING AN 8 CM-DIAMETER HOLE PLACED ON TOP OF A 500ML BEAKER CONTAINING LIQUID TO A DEPTH OF ABOUT 1 CM ABOVE THE IMMERSED SIEVING SURFACE. AS AN ADDITIONAL PRECAUTION A PIECE OF WIRE GAUZE OF ABOUT 60 TO 100 MESH IS INSERTED IN THE BEAKER TO ATTENUATE THE VIBRATIONS. THE BEAKER AND SIEVE ARE PLACED IN A CONVENTIONAL ULTRASONIC CLEANING BATH CONTAINING WATER UP TO THE LEVEL IN THE BEAKER. ULTRASONIC VIBRATIONS ARE GENERATED FOR 2 TO 3 MINUTES, THE BEAKER AND SIEVE ARE TAKEN OUT OF THE BATH AND THE SIEVE IS PLACED IN ANOTHER SIMILAR BEAKER CONTAINING FRESH LIQUID. THE PROCEDURE IS REPEATED UNTIL THE PASSAGE OF PARTICLES THROUGH THE SIEVE IS NEGLIGIBLE. THE SIEVE IS REMOVED, DRIED AT 70C TO CONSTANT WEIGHT, AND THE QUANTITY OF MATERIAL PASSED THROUGH THE SIEVE IS THUS DETERMINED.

About this research paper

What this paper is about

A SIMPLE AND RELIABLE TECHNIQUE IS DESCRIBED WHICH AVOIDS DAMAGE TO THE MICROMESHES INVOLVED IN SIEVING MATERIAL BELOW 20 MICROMETRES USING ULTRASONIC VIBRATIONS. THE SIEVE IS DRIED TO CONSTANT WEIGHT IN AN OVEN BELOW 70 DEGREES C AND COOLED IN A DESICCATOR. THE SIEVE AND ABOUT 1 GRAM OF THE SAMPLE ARE WEIGHED TO A PRECISION OF + OR - 0.2MG. THE SIEVE IS THEN FITTED LOOSELY INTO A METAL RETAINER PLATE CONTAINING AN 8 CM-DIAMETER HOLE PLACED ON TOP OF A 500ML BEAKER CONTAINING LIQUID TO A DEPTH OF ABOUT 1 CM ABOVE THE IMMERSED SIEVING SURFACE. AS AN ADDITIONAL PRECAUTION A PIECE OF WIRE GAUZE OF ABOUT 60 TO 100 MESH IS INSERTED IN THE BEAKER TO ATTENUATE THE VIBRATIONS. THE BEAKER AND SIEVE ARE PLACED IN A CONVENTIONAL ULTRASONIC CLEANING BATH CONTAINING WATER UP TO THE LEVEL IN THE BEAKER. ULTRASONIC VIBRATIONS ARE GENERATED FOR 2 TO 3 MINUTES, THE BEAKER AND SIEVE ARE TAKEN OUT OF THE BATH AND THE SIEVE IS PLACED IN ANOTHER SIMILAR BEAKER CONTAINING FRESH LIQUID. THE PROCEDURE IS REPEATED UNTIL THE PASSAGE OF PARTICLES THROUGH THE SIEVE IS NEGLIGIBLE. THE SIEVE IS REMOVED, DRIED AT 70C TO CONSTANT WEIGHT, AND THE QUANTITY OF MATERIAL PASSED THROUGH THE SIEVE IS THUS DETERMINED.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A SIMPLE AND RELIABLE TECHNIQUE IS DESCRIBED WHICH AVOIDS DAMAGE TO THE MICROMESHES INVOLVED IN SIEVING MATERIAL BELOW 20 MICROMETRES USING ULTRASONIC VIBRATIONS. THE SIEVE IS DRIED TO CONSTANT WEIGHT IN AN OVEN BELOW 70 DEGREES C AND COOLED IN A DESICCATOR. THE SIEVE AND ABOUT 1 GRAM OF THE SAMPLE ARE WEIGHED TO A PRECISION OF + OR - 0.2MG. THE SIEVE IS THEN FITTED LOOSELY INTO A METAL RETAINER PLATE CONTAINING AN 8 CM-DIAMETER HOLE PLACED ON TOP OF A 500ML BEAKER CONTAINING LIQUID TO A DEPTH OF ABOUT 1 CM ABOVE THE IMMERSED SIEVING SURFACE. AS AN ADDITIONAL PRECAUTION A PIECE OF WIRE GAUZE OF ABOUT 60 TO 100 MESH IS INSERTED IN THE BEAKER TO ATTENUATE THE VIBRATIONS. THE BEAKER AND SIEVE ARE PLACED IN A CONVENTIONAL ULTRASONIC CLEANING BATH CONTAINING WATER UP TO THE LEVEL IN THE BEAKER. ULTRASONIC VIBRATIONS ARE GENERATED FOR 2 TO 3 MINUTES, THE BEAKER AND SIEVE ARE TAKEN OUT OF THE BATH AND THE SIEVE IS PLACED IN ANOTHER SIMILAR BEAKER CONTAINING FRESH LIQUID. THE PROCEDURE IS REPEATED UNTIL THE PASSAGE OF PARTICLES THROUGH THE SIEVE IS NEGLIGIBLE. THE SIEVE IS REMOVED, DRIED AT 70C TO CONSTANT WEIGHT, AND THE QUANTITY OF MATERIAL PASSED THROUGH THE SIEVE IS THUS DETERMINED.

Key concepts: Sieve (category theory), Sieve analysis, Materials science, Beaker, Ultrasonic sensor, Particle (ecology), Composite material, Vibration

Related papers

Back to paper searchBrowse research topicsOriginal source
PARTICLE SIZE ANALYSIS WITH MICRO SIEVES USING ULTRASONIC VIBRATIONS — Research Paper | ScholarLens