Solid-Phase Extraction Combined with High Performance Liquid Chromatography-Diode Array Detector for Rapid Determination of Estrogens in Milk
Qinghua Yan, Li Yang, Sufang Li
Abstract
Open-access reader
Qinghua Yan, Li Yang, Sufang Li
Abstract
Open-access reader
Purpose: To develop a simple but effective method for the quantitative analysis of estrogens in milk.Methods: Solid-phase extraction method was employed for the extraction of the estrogen from milk and high performance liquid chromatography-diode array detector (HPLC-DAD) was used for the determination of estrogen.Results: Optimal chromatographic conditions were achieved on an Eclipse XDB-C18 column at a flow rate of 0.8 mL/min at room temperature. The products were monitored using a DAD detector set at 280 nm. The retention time of the three main estrogens were 15 min with a gradient program of acetonitrile/water, from 0 to 3 min, holding 35 % acetonitrile; from 4 to 7 min, ramped to 55 % acetonitrile; from 8 to 20 min, maintained at 55 % acetonitrile. The results showed that the calibration curve had good linearity within the concentration range of 0.5 - 8.0 μg/mL with correlation coefficient (R2) in the range of 0.9929-0.9936. The limit of detection was in the range of 0.025 - 0.045 μg/mL while mean recovery of estrogen from milk samples varied from 92.6 to 104.1 %. Satisfactory precision was obtained both for intra-assay (RSD, 1.8 to 4.4 %) and inter-assay (RSD, 2.0 to 4.7 %).Conclusion: The proposed method is environmentally friendly, inexpensive and convenient, and should be helpful in analyzing estrogens in biological, environmental and food samples.Keywords: Solid-phase extraction, Milk, Estrogens, High performance liquid chromatography-diode array detector
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose: To develop a simple but effective method for the quantitative analysis of estrogens in milk.Methods: Solid-phase extraction method was employed for the extraction of the estrogen from milk and high performance liquid chromatography-diode array detector (HPLC-DAD) was used for the determination of estrogen.Results: Optimal chromatographic conditions were achieved on an Eclipse XDB-C18 column at a flow rate of 0.8 mL/min at room temperature. The products were monitored using a DAD detector set at 280 nm. The retention time of the three main estrogens were 15 min with a gradient program of acetonitrile/water, from 0 to 3 min, holding 35 % acetonitrile; from 4 to 7 min, ramped to 55 % acetonitrile; from 8 to 20 min, maintained at 55 % acetonitrile. The results showed that the calibration curve had good linearity within the concentration range of 0.5 - 8.0 μg/mL with correlation coefficient (R2) in the range of 0.9929-0.9936. The limit of detection was in the range of 0.025 - 0.045 μg/mL while mean recovery of estrogen from milk samples varied from 92.6 to 104.1 %. Satisfactory precision was obtained both for intra-assay (RSD, 1.8 to 4.4 %) and inter-assay (RSD, 2.0 to 4.7 %).Conclusion: The proposed method is environmentally friendly, inexpensive and convenient, and should be helpful in analyzing estrogens in biological, environmental and food samples.Keywords: Solid-phase extraction, Milk, Estrogens, High performance liquid chromatography-diode array detector
Key concepts: Chromatography, Acetonitrile, Extraction (chemistry), Chromatography detector, High-performance liquid chromatography, Chemistry, Detection limit, Calibration curve