Design and Performance Study of a Hot Water Driven 5 TR Capacity Absorption Cooling System
Anil Kumar Sharma, Bimal Kumar Mishra, Abhinav Dinesh, Ashok Misra
Abstract
Open-access reader
Anil Kumar Sharma, Bimal Kumar Mishra, Abhinav Dinesh, Ashok Misra
Abstract
Open-access reader
Use of high grade electrical energy, generated from fossil fuels, for cooling has increased environmental concerns like global warming and ozone layer depletion.Hence, there is a need to reduce dependence on them and explore potential environmental friendly options.In this aspect, vapor absorption system has scope of utilizing low grade energy source i.e. hot water from solar panel, to generate cooling effect and are environment friendly as no chloro-floro-carbons are used.The most usual combination of absorber refrigerant pair in such system is lithium bromide water (LiBr-H 2 O), where water vapor is the refrigerant.In present work, a hot water driven, single stage, absorption cooling system, using a lithium bromide water solution, is analyzed for determining the effect of various parameters on coefficient of performance (COP).Four basic stages in the absorption cycle are generation, condensation, evaporation and absorption with ideally no moving part.A configuration of theses four stages, having 5 TR cooling capacity is determined and examined for the variation in COP corresponds to the change in pressure and concentration.The pressure parameter is varied in condenser and evaporator, resulting graph shows that the increment in pressure of evaporator increases the COP whereas increment of pressure in condenser decreases the COP.At lower inlet concentration of LiBr solution to the absorber gives increment in COP.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Use of high grade electrical energy, generated from fossil fuels, for cooling has increased environmental concerns like global warming and ozone layer depletion.Hence, there is a need to reduce dependence on them and explore potential environmental friendly options.In this aspect, vapor absorption system has scope of utilizing low grade energy source i.e. hot water from solar panel, to generate cooling effect and are environment friendly as no chloro-floro-carbons are used.The most usual combination of absorber refrigerant pair in such system is lithium bromide water (LiBr-H 2 O), where water vapor is the refrigerant.In present work, a hot water driven, single stage, absorption cooling system, using a lithium bromide water solution, is analyzed for determining the effect of various parameters on coefficient of performance (COP).Four basic stages in the absorption cycle are generation, condensation, evaporation and absorption with ideally no moving part.A configuration of theses four stages, having 5 TR cooling capacity is determined and examined for the variation in COP corresponds to the change in pressure and concentration.The pressure parameter is varied in condenser and evaporator, resulting graph shows that the increment in pressure of evaporator increases the COP whereas increment of pressure in condenser decreases the COP.At lower inlet concentration of LiBr solution to the absorber gives increment in COP.
Key concepts: Water cooling, Environmental science, Absorption (acoustics), Materials science, Nuclear engineering, Atmospheric sciences, Thermodynamics, Engineering