Evaluation of gallbladder motility: comparison of two-dimensional and three-dimensional ultrasonography
Susanne Stads, Niels G. Venneman, Robert C.H. Scheffer, Melvin Samsom, Karel J. van Erpecum
Abstract
Open-access reader
Susanne Stads, Niels G. Venneman, Robert C.H. Scheffer, Melvin Samsom, Karel J. van Erpecum
Abstract
Open-access reader
Since impaired gallbladder emptying contributes to gallstone formation, the evaluation of gallbladder motility requires accurate methodology. Recently developed 3-dimensional ultrasonography may take into account various gallbladder shapes more accurately than conventional 2-dimensional ultrasonography. Therefore, volumes of water-filled balloons of various sizes were determined in vitro by 2-dimensional ultrasonography with the sum of cylinders method and by 3-dimensional ultrasonography. Also, in 15 gallstone patients and 6 healthy volunteers, fasting gallbladder volumes and postprandial motility were determined by both methods. Volumes of water-filled balloons as measured by both methods correlated strongly with true volumes (R= 0.93 for 2-dimensional and R = 0.98 for 3- dimensional ultrasonography). Gallbladder volumes measured by both methods were also correlated (R = 0.66, P <0.001). In gallstone patients, 3-dimensional ultrasonography yielded smaller gallbladder volumes than 2-dimensional ultrasonography (P = 0.007), but not in healthy subjects. With both methods, gallstone patients exhibited decreased postprandial gallbladder motility compared to healthy subjects. In conclusion, gallbladder volume measurements by 3-dimensional and 2-dimensional ultrasonography are strongly correlated.Nevertheless, in gallstone patients, gallbladder volumes by 3-dimensional ultrasonography tend to be smaller than by 2-dimensional ultrasonography, possibly due to interference of gallstones with the volume measurement.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Since impaired gallbladder emptying contributes to gallstone formation, the evaluation of gallbladder motility requires accurate methodology. Recently developed 3-dimensional ultrasonography may take into account various gallbladder shapes more accurately than conventional 2-dimensional ultrasonography. Therefore, volumes of water-filled balloons of various sizes were determined in vitro by 2-dimensional ultrasonography with the sum of cylinders method and by 3-dimensional ultrasonography. Also, in 15 gallstone patients and 6 healthy volunteers, fasting gallbladder volumes and postprandial motility were determined by both methods. Volumes of water-filled balloons as measured by both methods correlated strongly with true volumes (R= 0.93 for 2-dimensional and R = 0.98 for 3- dimensional ultrasonography). Gallbladder volumes measured by both methods were also correlated (R = 0.66, P <0.001). In gallstone patients, 3-dimensional ultrasonography yielded smaller gallbladder volumes than 2-dimensional ultrasonography (P = 0.007), but not in healthy subjects. With both methods, gallstone patients exhibited decreased postprandial gallbladder motility compared to healthy subjects. In conclusion, gallbladder volume measurements by 3-dimensional and 2-dimensional ultrasonography are strongly correlated.Nevertheless, in gallstone patients, gallbladder volumes by 3-dimensional ultrasonography tend to be smaller than by 2-dimensional ultrasonography, possibly due to interference of gallstones with the volume measurement.
Key concepts: Gallbladder, Ultrasonography, Medicine, Gallstones, Postprandial, Radiology, Gastroenterology, Internal medicine