2013PubMedOpen access

Determination of linezolid in human serum by reversed-phase high-performance liquid chromatography with ultraviolet and diode array detection.

Agnieszka Cios, Kamil Kuś, Joanna Szymura‐Oleksiak

Open full text 16 citations

Abstract

A high-performance liquid chromatographic (HPLC) method with UV and DAD detection for the quantitative determination of linezolid in human serum was developed in present work. Chromatography was carried out by reversed-phase technique on a RP-18 column with a mobile phase composed of 50 mM phosphate buffer and acetonitrile (76 : 26, v/v), adjusted to pH 3.5 with orthophosphoric acid. Serum samples were deproteinized with methanol centrifuged and then, the supernatant was analyzed using HPLC procedure. No interference was observed at the retention times of linezolid from blank serum or ten commonly used antibiotics. A concentration range from 0.50 to 30.0 g/mL was utilized to construct calibration curves. The lower limit of detection was determined to be 0.1 microg/mL of serum for both detectors. The lower limit of quantification of 0.25 microg/mL (CV = 2.6%) was established for determination using HPLC-UV and 0.5 microg/mL (CV = 5.42%) for HPLC-DAD. The recovery of linezolid was approximately 100%. Intra-day accuracy ranged from 0.97 to 12.63% and 0.74 to 10.85% for HPLC-UV and HPLC-DAD method, respectively. Intra-day precision was less than 4.69% for HPLC-UV and less than 5.42% for HPLC-DAD method. Tests confirmed the stability of linezolid in serum during three freeze-thaw cycles and during long-term storage of frozen serum for up to 6 weeks; in extracts it was stable in the HPLC autosampler over 24 h. Statistical analysis by Student's t-test showed no significant difference between the results obtained by these two methods. In summary, these methods will be used and adapted for infected patients in intensive care unit, to determine linezolid serum concentrations in order to know the pharmacokinetic profiles of linezolid.

Open-access reader

About this research paper

What this paper is about

A high-performance liquid chromatographic (HPLC) method with UV and DAD detection for the quantitative determination of linezolid in human serum was developed in present work. Chromatography was carried out by reversed-phase technique on a RP-18 column with a mobile phase composed of 50 mM phosphate buffer and acetonitrile (76 : 26, v/v), adjusted to pH 3.5 with orthophosphoric acid. Serum samples were deproteinized with methanol centrifuged and then, the supernatant was analyzed using HPLC procedure. No interference was observed at the retention times of linezolid from blank serum or ten commonly used antibiotics. A concentration range from 0.50 to 30.0 g/mL was utilized to construct calibration curves. The lower limit of detection was determined to be 0.1 microg/mL of serum for both detectors. The lower limit of quantification of 0.25 microg/mL (CV = 2.6%) was established for determination using HPLC-UV and 0.5 microg/mL (CV = 5.42%) for HPLC-DAD. The recovery of linezolid was approximately 100%. Intra-day accuracy ranged from 0.97 to 12.63% and 0.74 to 10.85% for HPLC-UV and HPLC-DAD method, respectively. Intra-day precision was less than 4.69% for HPLC-UV and less than 5.42% for HPLC-DAD method. Tests confirmed the stability of linezolid in serum during three freeze-thaw cycles and during long-term storage of frozen serum for up to 6 weeks; in extracts it was stable in the HPLC autosampler over 24 h. Statistical analysis by Student's t-test showed no significant difference between the results obtained by these two methods. In summary, these methods will be used and adapted for infected patients in intensive care unit, to determine linezolid serum concentrations in order to know the pharmacokinetic profiles of linezolid.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high-performance liquid chromatographic (HPLC) method with UV and DAD detection for the quantitative determination of linezolid in human serum was developed in present work. Chromatography was carried out by reversed-phase technique on a RP-18 column with a mobile phase composed of 50 mM phosphate buffer and acetonitrile (76 : 26, v/v), adjusted to pH 3.5 with orthophosphoric acid. Serum samples were deproteinized with methanol centrifuged and then, the supernatant was analyzed using HPLC procedure. No interference was observed at the retention times of linezolid from blank serum or ten commonly used antibiotics. A concentration range from 0.50 to 30.0 g/mL was utilized to construct calibration curves. The lower limit of detection was determined to be 0.1 microg/mL of serum for both detectors. The lower limit of quantification of 0.25 microg/mL (CV = 2.6%) was established for determination using HPLC-UV and 0.5 microg/mL (CV = 5.42%) for HPLC-DAD. The recovery of linezolid was approximately 100%. Intra-day accuracy ranged from 0.97 to 12.63% and 0.74 to 10.85% for HPLC-UV and HPLC-DAD method, respectively. Intra-day precision was less than 4.69% for HPLC-UV and less than 5.42% for HPLC-DAD method. Tests confirmed the stability of linezolid in serum during three freeze-thaw cycles and during long-term storage of frozen serum for up to 6 weeks; in extracts it was stable in the HPLC autosampler over 24 h. Statistical analysis by Student's t-test showed no significant difference between the results obtained by these two methods. In summary, these methods will be used and adapted for infected patients in intensive care unit, to determine linezolid serum concentrations in order to know the pharmacokinetic profiles of linezolid.

Key concepts: High-performance liquid chromatography, Chromatography, Detection limit, Chemistry, Linezolid, Chromatography detector, Quantitative analysis (chemistry), Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of linezolid in human serum by reversed-phase high-performance liquid chromatography with ultraviolet and diode array detection. — Research Paper | ScholarLens