2011•Unpublished venueRequires access

RP HPLC Method for the determination of Tamsulosin in bulk and Pharmaceutical formulations

Manish Kumar Thimmaraju, V. V. R. Narasimha Rao, P. Siddartha Kumar, P. Siddartha

Open publisher page 10 citations

Abstract

A simple, sensitive, precise and specific reverse phase high performance liquid chromatographic method was developed and validated for the determination of Tamsulosin in bulk and tablet dosage forms. It was found that the excipient in the tablet dosage forms does not interfere in the quantification of active drug by proposed method. The HPLC separation was carried out by reverse phase chromatography on Shimadzu HPLC, 10-At detector with hypersil ODS C18 Column 250 X 4.6 mm (particle size of 5µ) and constant flow pump. Rheodyne injector with 20 µl loop with a mobile phase composed in the ratio acetonitrile: (0.05M) KH2PO4 buffer (45:55) at flow rate 1.8 ml /min. The detection was monitored at 240nm. The calibration curve for Tamsulosin was linear from 10-50g/ml and internal standard (Bromhexine) 10g/ml were prepared by suitable dilutions of the stock solution with appropriate mobile phase. The interday and intraday precision was found to be within limits. The proposed method has adequate sensitivity, reproducibility and specificity for the determination of Tamsulosin in bulk and its tablet dosage forms. LOD and LOQ for Tamsulosin were found to be 0.495 and 0.461.Accuracy (recoveries: 98.5-98.55%) and reproducibility were found to satisfactory.

About this research paper

What this paper is about

A simple, sensitive, precise and specific reverse phase high performance liquid chromatographic method was developed and validated for the determination of Tamsulosin in bulk and tablet dosage forms. It was found that the excipient in the tablet dosage forms does not interfere in the quantification of active drug by proposed method. The HPLC separation was carried out by reverse phase chromatography on Shimadzu HPLC, 10-At detector with hypersil ODS C18 Column 250 X 4.6 mm (particle size of 5µ) and constant flow pump. Rheodyne injector with 20 µl loop with a mobile phase composed in the ratio acetonitrile: (0.05M) KH2PO4 buffer (45:55) at flow rate 1.8 ml /min. The detection was monitored at 240nm. The calibration curve for Tamsulosin was linear from 10-50g/ml and internal standard (Bromhexine) 10g/ml were prepared by suitable dilutions of the stock solution with appropriate mobile phase. The interday and intraday precision was found to be within limits. The proposed method has adequate sensitivity, reproducibility and specificity for the determination of Tamsulosin in bulk and its tablet dosage forms. LOD and LOQ for Tamsulosin were found to be 0.495 and 0.461.Accuracy (recoveries: 98.5-98.55%) and reproducibility were found to satisfactory.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, sensitive, precise and specific reverse phase high performance liquid chromatographic method was developed and validated for the determination of Tamsulosin in bulk and tablet dosage forms. It was found that the excipient in the tablet dosage forms does not interfere in the quantification of active drug by proposed method. The HPLC separation was carried out by reverse phase chromatography on Shimadzu HPLC, 10-At detector with hypersil ODS C18 Column 250 X 4.6 mm (particle size of 5µ) and constant flow pump. Rheodyne injector with 20 µl loop with a mobile phase composed in the ratio acetonitrile: (0.05M) KH2PO4 buffer (45:55) at flow rate 1.8 ml /min. The detection was monitored at 240nm. The calibration curve for Tamsulosin was linear from 10-50g/ml and internal standard (Bromhexine) 10g/ml were prepared by suitable dilutions of the stock solution with appropriate mobile phase. The interday and intraday precision was found to be within limits. The proposed method has adequate sensitivity, reproducibility and specificity for the determination of Tamsulosin in bulk and its tablet dosage forms. LOD and LOQ for Tamsulosin were found to be 0.495 and 0.461.Accuracy (recoveries: 98.5-98.55%) and reproducibility were found to satisfactory.

Key concepts: Chromatography, Reproducibility, Calibration curve, Particle size, High-performance liquid chromatography, Dosage form, Chemistry, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
RP HPLC Method for the determination of Tamsulosin in bulk and Pharmaceutical formulations — Research Paper | ScholarLens