DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF AMLODIPINE BESYLATE, LOSARTAN POTASSIUM AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM
Gurlin kaur, Suresh Jain, Vipin Saini, J Ayyappan
Abstract
Gurlin kaur, Suresh Jain, Vipin Saini, J Ayyappan
Abstract
Objective: The present work aims to develop and validate a simple, specific, and accurate reverse phase high performance liquid chromatographic method for the simultaneous estimation of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide. Method: The method was developed and validated using Inertsil C8 column (150mm x 4.6 mm, 5µ), with mobile phase consisting of acetonitrile: buffer (700: 500 v/v) with flow rate of 1.0 ml/minute (UV detection 254 nm). Results: The retention times of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide were found to be 3.32 min, 2.57 min and 1.92 min respectively. Linearity was observed over a wide concentration range with fairly good sensitivity of 25-75 µg/ml for Amlodipine Besylate (R2 =0.9997), 249-747 µg/ml for Losartan Potassium (R2 =0.9991) and 62-188 µg/ml for Hydrochlorothiazide (R2 =1.000). The percentage recoveries of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide were found to be in the range of 99-101 %, 98%-100 % & 98-101% respectively. Conclusion: The proposed method is rapid, accurate and can be used for the routine analysis of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide in their formulations.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: The present work aims to develop and validate a simple, specific, and accurate reverse phase high performance liquid chromatographic method for the simultaneous estimation of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide. Method: The method was developed and validated using Inertsil C8 column (150mm x 4.6 mm, 5µ), with mobile phase consisting of acetonitrile: buffer (700: 500 v/v) with flow rate of 1.0 ml/minute (UV detection 254 nm). Results: The retention times of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide were found to be 3.32 min, 2.57 min and 1.92 min respectively. Linearity was observed over a wide concentration range with fairly good sensitivity of 25-75 µg/ml for Amlodipine Besylate (R2 =0.9997), 249-747 µg/ml for Losartan Potassium (R2 =0.9991) and 62-188 µg/ml for Hydrochlorothiazide (R2 =1.000). The percentage recoveries of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide were found to be in the range of 99-101 %, 98%-100 % & 98-101% respectively. Conclusion: The proposed method is rapid, accurate and can be used for the routine analysis of Amlodipine Besylate, Losartan Potassium and Hydrochlorothiazide in their formulations.
Key concepts: Hydrochlorothiazide, Losartan Potassium, Amlodipine, Losartan, Chromatography, Chemistry, Potassium, High-performance liquid chromatography