2012Unpublished venueRequires access

INFLUENCE OF WATER TEMPERATURE ON HEAT TRANSFER COEFFICIENT IN SPRAY COOLING OF STEEL SURFACES

M. Chabi, Milan Hnízdil

Open publisher page 1 citations

Abstract

Cooling of stainless steel surfaces with flat fan nozzles was studied experimentally. Several configurations of jets and pressures were tested. Tests were done with variable coolant (water) temperatures (20 °C, 40 °C, 60 °C and 80 °C). The influence of coolant temperature on the heat transfer coefficient was investigated. An increase in coolant temperature caused a significant decrease of the Leidenfrost temperature (temperature at which the character of boiling is changed - the film boiling is changed into nucleate boiling). Changing the water temperature from 20 °C to 80 °C caused a change of the Leidenfrost temperature of about 140 °C. Furthermore it was observed that in a high temperature region (above Leidenfrost temperature) the heat transfer coefficient has the highest value for the lowest water temperature and for the high coolant temperature (80 °C) the cooling intensity is the lowest.

About this research paper

What this paper is about

Cooling of stainless steel surfaces with flat fan nozzles was studied experimentally. Several configurations of jets and pressures were tested. Tests were done with variable coolant (water) temperatures (20 °C, 40 °C, 60 °C and 80 °C). The influence of coolant temperature on the heat transfer coefficient was investigated. An increase in coolant temperature caused a significant decrease of the Leidenfrost temperature (temperature at which the character of boiling is changed - the film boiling is changed into nucleate boiling). Changing the water temperature from 20 °C to 80 °C caused a change of the Leidenfrost temperature of about 140 °C. Furthermore it was observed that in a high temperature region (above Leidenfrost temperature) the heat transfer coefficient has the highest value for the lowest water temperature and for the high coolant temperature (80 °C) the cooling intensity is the lowest.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Cooling of stainless steel surfaces with flat fan nozzles was studied experimentally. Several configurations of jets and pressures were tested. Tests were done with variable coolant (water) temperatures (20 °C, 40 °C, 60 °C and 80 °C). The influence of coolant temperature on the heat transfer coefficient was investigated. An increase in coolant temperature caused a significant decrease of the Leidenfrost temperature (temperature at which the character of boiling is changed - the film boiling is changed into nucleate boiling). Changing the water temperature from 20 °C to 80 °C caused a change of the Leidenfrost temperature of about 140 °C. Furthermore it was observed that in a high temperature region (above Leidenfrost temperature) the heat transfer coefficient has the highest value for the lowest water temperature and for the high coolant temperature (80 °C) the cooling intensity is the lowest.

Key concepts: Leidenfrost effect, Nucleate boiling, Coolant, Heat transfer coefficient, Boiling, Thermodynamics, Heat transfer, Nozzle

Related papers

Back to paper searchBrowse research topicsOriginal source
INFLUENCE OF WATER TEMPERATURE ON HEAT TRANSFER COEFFICIENT IN SPRAY COOLING OF STEEL SURFACES — Research Paper | ScholarLens