1992•PubMedRequires access

Quantitative measurement of regional cerebral blood flow using N-isopropyl-(iodine-123)p-iodoamphetamine and single-photon emission computed tomography.

Gen Takeshita, Hisato Maeda, Kaori Nakane, Hiroshi Toyama, Eiji Sakakibara, Satoshi Komai, Akira Takeuchi, Sukehiko Koga, Mototsugu Ono, Tsuyoshi Nakagawa

Open publisher page 15 citations

Abstract

We have developed a quantitative method of measuring regional cerebral blood flow (rCBF) by using N-isopropyl-(iodine-123)p-iodoamphetamine and single-photon emission computed tomography (SPECT). Twenty-five dynamic SPECT images (24 sec/scan) were collected immediately after tracer injection using a ring-type SPECT system and the accumulation curve (C(t)) was obtained. The time-activity curve corresponding to the arterial blood activity curve was used as B(t). The latter curve was calculated from the lung time-activity curve monitored during scanning and corrected by the actual activity obtained by one-point blood sampling 5 min after tracer injection. The octanol extraction ratio during scanning was considered to be constant and taken as the value measured 5 min after tracer injection (E). The uptake constant (K) per pixel was calculated by the least squares fitting method as the slope of the linear relationship in which C(t)/E x B(t) was plotted against E x integral of t(o)B(tau)d tau/E x B(t). Functional maps of rCBF values were obtained on a 64 x 64 matrix by calculating the uptake constant per pixel and the cross calibration factor (CF) between the SPECT system and a well counter (rCBF = K.CF x 100).

About this research paper

What this paper is about

We have developed a quantitative method of measuring regional cerebral blood flow (rCBF) by using N-isopropyl-(iodine-123)p-iodoamphetamine and single-photon emission computed tomography (SPECT). Twenty-five dynamic SPECT images (24 sec/scan) were collected immediately after tracer injection using a ring-type SPECT system and the accumulation curve (C(t)) was obtained. The time-activity curve corresponding to the arterial blood activity curve was used as B(t). The latter curve was calculated from the lung time-activity curve monitored during scanning and corrected by the actual activity obtained by one-point blood sampling 5 min after tracer injection. The octanol extraction ratio during scanning was considered to be constant and taken as the value measured 5 min after tracer injection (E). The uptake constant (K) per pixel was calculated by the least squares fitting method as the slope of the linear relationship in which C(t)/E x B(t) was plotted against E x integral of t(o)B(tau)d tau/E x B(t). Functional maps of rCBF values were obtained on a 64 x 64 matrix by calculating the uptake constant per pixel and the cross calibration factor (CF) between the SPECT system and a well counter (rCBF = K.CF x 100).

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have developed a quantitative method of measuring regional cerebral blood flow (rCBF) by using N-isopropyl-(iodine-123)p-iodoamphetamine and single-photon emission computed tomography (SPECT). Twenty-five dynamic SPECT images (24 sec/scan) were collected immediately after tracer injection using a ring-type SPECT system and the accumulation curve (C(t)) was obtained. The time-activity curve corresponding to the arterial blood activity curve was used as B(t). The latter curve was calculated from the lung time-activity curve monitored during scanning and corrected by the actual activity obtained by one-point blood sampling 5 min after tracer injection. The octanol extraction ratio during scanning was considered to be constant and taken as the value measured 5 min after tracer injection (E). The uptake constant (K) per pixel was calculated by the least squares fitting method as the slope of the linear relationship in which C(t)/E x B(t) was plotted against E x integral of t(o)B(tau)d tau/E x B(t). Functional maps of rCBF values were obtained on a 64 x 64 matrix by calculating the uptake constant per pixel and the cross calibration factor (CF) between the SPECT system and a well counter (rCBF = K.CF x 100).

Key concepts: Iodine-123, Single-photon emission computed tomography, Nuclear medicine, TRACER, Cerebral blood flow, Emission computed tomography, Chemistry, Blood flow