Quantification of renal function with a count-based gamma camera method using technetium-99m-MAG3 in children.
Kazuo Itoh, Katsuya Nonomura, Tetsufumi Yamashita, Kakuko Kanegae, Masashi Murakumo, Tomohiko Koyanagi, M Furudate
Abstract
Kazuo Itoh, Katsuya Nonomura, Tetsufumi Yamashita, Kakuko Kanegae, Masashi Murakumo, Tomohiko Koyanagi, M Furudate
Abstract
UNLABELLED: To evaluate renal function quantitatively without blood sampling in children, renal uptake by gamma camera renography using 99mTc-MAG3 was compared with plasma clearance by a single blood sample method as the reference. METHODS: Twenty children (15 boys, 5 girls; aged 2-14 yr) with nephrourological diseases were examined prospectively in this study. The patient received an intravenous administration of 5 MBq/kg 99mTc-MAG3 which was prepared using a commercially available kit. Gamma camera renography was performed and the renal uptake per injected dose (%RU) of the 1-min period of postinjection was calculated from a background-corrected renogram curve by computer. The plasma clearance (Clmag) of 99mTc-MAG3 was calculated by the single blood sample method at 35 min postinjection. RESULTS: The %RU of the 1-min period in the 1-3 min postinjection correlated well with Clmag. The best correlation was observed 1-2 min postinjection. The regression equation between total %RU (X) and Clmag (Y) (ml/min/1.73 m2) was Y = -98.509 + 20.373X (r = 0.910, s = 84.19) with standardization by BSA. The best fit regression equation between individual %RU (X) and Clmag (Y) (ml/min/1.73m2) was Y = -43.799 + 19.917X (p = 0.932, s = 43.27). CONCLUSION: The renal uptake method based on separate counts by gamma camera renography using 99mTc-MAG3 does not require a blood sample for quantification of renal function and may be potentially more practical in children.
OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
UNLABELLED: To evaluate renal function quantitatively without blood sampling in children, renal uptake by gamma camera renography using 99mTc-MAG3 was compared with plasma clearance by a single blood sample method as the reference. METHODS: Twenty children (15 boys, 5 girls; aged 2-14 yr) with nephrourological diseases were examined prospectively in this study. The patient received an intravenous administration of 5 MBq/kg 99mTc-MAG3 which was prepared using a commercially available kit. Gamma camera renography was performed and the renal uptake per injected dose (%RU) of the 1-min period of postinjection was calculated from a background-corrected renogram curve by computer. The plasma clearance (Clmag) of 99mTc-MAG3 was calculated by the single blood sample method at 35 min postinjection. RESULTS: The %RU of the 1-min period in the 1-3 min postinjection correlated well with Clmag. The best correlation was observed 1-2 min postinjection. The regression equation between total %RU (X) and Clmag (Y) (ml/min/1.73 m2) was Y = -98.509 + 20.373X (r = 0.910, s = 84.19) with standardization by BSA. The best fit regression equation between individual %RU (X) and Clmag (Y) (ml/min/1.73m2) was Y = -43.799 + 19.917X (p = 0.932, s = 43.27). CONCLUSION: The renal uptake method based on separate counts by gamma camera renography using 99mTc-MAG3 does not require a blood sample for quantification of renal function and may be potentially more practical in children.
Key concepts: Gamma camera, Nuclear medicine, Technetium, Renal function, Technetium-99m, Blood sampling, Medicine, Urology