2014•Unpublished venueRequires access

Development and validation of RP-HPLC method for the simultaneous estimation of naproxen sodium and esomeprazole magnesium in pharmaceutical tablet dosage form

Srinivas Ampati

Open publisher page 2 citations

Abstract

An isocratic RP-HPLC method was developed and validated for the Simultaneous estimation of Naproxen sodium and Esomeprazole magnesium trihydrate in Pharmaceutical tablet dosage form. The separation was achieved by using a reversed-phase C18column(Thermo eletrole, ODS, 250mm × 4.6 mm i.d, 5μm) at ambient temperature with mobile phase consisting of Phosphate buffer (pH adjust to 3.8using OPA): Acetonitrile : Methanol (30:50:20v/v). The flow rate was 1.0 ml/min. Detection was carried out at a wavelength of 220 nm. Retention time of Naproxen sodium and Esomeprazole magnesium trihydrate were found tobe2.417 and 3.903min respectively. The proposed method was validated for selectivity, precision, linearity and accuracy. The assay method was found to be linear from 75-175µg/ml and 3-7µg/ml for Naproxen sodium and Esomeprazole magnesium trihydrate respectively. All validation parameters were within the acceptable range. The developed method was successfully applied to estimate the amount of Naproxen sodium and Esomeprazole magnesium trihydrate in Pharmaceutical tablet dosage form.

About this research paper

What this paper is about

An isocratic RP-HPLC method was developed and validated for the Simultaneous estimation of Naproxen sodium and Esomeprazole magnesium trihydrate in Pharmaceutical tablet dosage form. The separation was achieved by using a reversed-phase C18column(Thermo eletrole, ODS, 250mm × 4.6 mm i.d, 5μm) at ambient temperature with mobile phase consisting of Phosphate buffer (pH adjust to 3.8using OPA): Acetonitrile : Methanol (30:50:20v/v). The flow rate was 1.0 ml/min. Detection was carried out at a wavelength of 220 nm. Retention time of Naproxen sodium and Esomeprazole magnesium trihydrate were found tobe2.417 and 3.903min respectively. The proposed method was validated for selectivity, precision, linearity and accuracy. The assay method was found to be linear from 75-175µg/ml and 3-7µg/ml for Naproxen sodium and Esomeprazole magnesium trihydrate respectively. All validation parameters were within the acceptable range. The developed method was successfully applied to estimate the amount of Naproxen sodium and Esomeprazole magnesium trihydrate in Pharmaceutical tablet dosage form.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An isocratic RP-HPLC method was developed and validated for the Simultaneous estimation of Naproxen sodium and Esomeprazole magnesium trihydrate in Pharmaceutical tablet dosage form. The separation was achieved by using a reversed-phase C18column(Thermo eletrole, ODS, 250mm × 4.6 mm i.d, 5μm) at ambient temperature with mobile phase consisting of Phosphate buffer (pH adjust to 3.8using OPA): Acetonitrile : Methanol (30:50:20v/v). The flow rate was 1.0 ml/min. Detection was carried out at a wavelength of 220 nm. Retention time of Naproxen sodium and Esomeprazole magnesium trihydrate were found tobe2.417 and 3.903min respectively. The proposed method was validated for selectivity, precision, linearity and accuracy. The assay method was found to be linear from 75-175µg/ml and 3-7µg/ml for Naproxen sodium and Esomeprazole magnesium trihydrate respectively. All validation parameters were within the acceptable range. The developed method was successfully applied to estimate the amount of Naproxen sodium and Esomeprazole magnesium trihydrate in Pharmaceutical tablet dosage form.

Key concepts: Naproxen Sodium, Dosage form, Esomeprazole, Chromatography, Naproxen, Chemistry, Sodium, Magnesium

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and validation of RP-HPLC method for the simultaneous estimation of naproxen sodium and esomeprazole magnesium in pharmaceutical tablet dosage form — Research Paper | ScholarLens