Effect of the Level of Expiration on Body Density Measurement

B. E. Welch, C. E. Crisp

Open publisher page 11 citations

Abstract

This experiment was designed to test the reproducibility of body density measurements following maximum and approximately one-half maximum expiration. A total of 26 adult males were tested. Duplicate density measurements were made at each level of expiration. The average lung volume following maximum expiration was 1.66 liters. The average density following maximum expiration (d = 1.0559 gm/cc) was 0.0017 density units lower than that determined following one-half maximum expiration. This difference was significant (P < 0.01). Each technique was consistent within itself; the standard deviation of the maximum expiration replicates being 0.0018, and the one-half maximum expiration replicates 0.0024. The latter differences were not significant. Note: with the technical assistance of R. S. Isenstein and W. C. Roemer. Submitted on September 23, 1957

About this research paper

What this paper is about

This experiment was designed to test the reproducibility of body density measurements following maximum and approximately one-half maximum expiration. A total of 26 adult males were tested. Duplicate density measurements were made at each level of expiration. The average lung volume following maximum expiration was 1.66 liters. The average density following maximum expiration (d = 1.0559 gm/cc) was 0.0017 density units lower than that determined following one-half maximum expiration. This difference was significant (P < 0.01). Each technique was consistent within itself; the standard deviation of the maximum expiration replicates being 0.0018, and the one-half maximum expiration replicates 0.0024. The latter differences were not significant. Note: with the technical assistance of R. S. Isenstein and W. C. Roemer. Submitted on September 23, 1957

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This experiment was designed to test the reproducibility of body density measurements following maximum and approximately one-half maximum expiration. A total of 26 adult males were tested. Duplicate density measurements were made at each level of expiration. The average lung volume following maximum expiration was 1.66 liters. The average density following maximum expiration (d = 1.0559 gm/cc) was 0.0017 density units lower than that determined following one-half maximum expiration. This difference was significant (P < 0.01). Each technique was consistent within itself; the standard deviation of the maximum expiration replicates being 0.0018, and the one-half maximum expiration replicates 0.0024. The latter differences were not significant. Note: with the technical assistance of R. S. Isenstein and W. C. Roemer. Submitted on September 23, 1957

Key concepts: Expiration, Reproducibility, Expiration date, Standard deviation, Lung volumes, Mathematics, Volume (thermodynamics), Statistics