2008•Çanakkale Onsekiz Mart University AVESISRequires access

Spectrophotometric and High Performance Liquid Chromatographic Determination of Fexofenadine Hydrochloride in Pharmaceutical Formulations

KARACAN, ELİF, Feyyaz Onur, Palabiyik, Ismail Murat, Kozan, Ismail

Open publisher page 7 citations

Abstract

In present study, three new spectrophotometric methods, original UV spectrophotom etry, first and second order derivative UV spectrophotometry and a new HPLC method were developed for the determination of fexofenadine HCl (FEX) in pharmaceutical preparations. In original UV spectrophotometry, absorbances were measured at 258.7 nm in the zero order UV spectra of the solution of FEX in methanol-water (1:1) in the range of 220 - 290 nm. In first derivative UV spectrophotometry, dA/dl values were measured at 270.4 nm in the first derivative UV spectra of the solution of FEX in methanol-water (1:1) in the range of 245 - 285 nm (AX= 2 nm). In second derivative UV spectrophotometry d2A/dI2 values were measured at 252.84 nm in the second derivative UV spectra of the solution of FEX in methanol-water (1:1) in the range of 245 - 285 nm (AX= 2 nm). Linearity range was found as 100.0 - 1000.0 jjg/mL in all the spectrophotometric methods. Mean recoveries and the relative standard deviations of the methods were found as 99.55 % and 1.10 % in original UV spectrophotometry, 100.97 % and 1.09 % in first derivative UV spectrophotometry and, 99.25 % and 1.10 % in second derivative UV spectrophotometry respectively. In HPLC method, an isocratic system consisted of an ACE C18 analytical column and a mobile phase composed of methanol - phosphate buffer (pH 3.0, 0.1 M) (95:5, v/v) at a flow rate 1.0 mL/min was used for the optimal chromatographic separation using UV detection at 220 nm. Diflucortolone valerate was used as internal standard. Mean recoveries and the relative standard deviations was found as 100.23 % and 0.54 % in HPLC method. All the methods developed were successfully applied to five tablet formulations commercially available in Turkish drug market and the results were compared statistically with each other.

About this research paper

What this paper is about

In present study, three new spectrophotometric methods, original UV spectrophotom etry, first and second order derivative UV spectrophotometry and a new HPLC method were developed for the determination of fexofenadine HCl (FEX) in pharmaceutical preparations. In original UV spectrophotometry, absorbances were measured at 258.7 nm in the zero order UV spectra of the solution of FEX in methanol-water (1:1) in the range of 220 - 290 nm. In first derivative UV spectrophotometry, dA/dl values were measured at 270.4 nm in the first derivative UV spectra of the solution of FEX in methanol-water (1:1) in the range of 245 - 285 nm (AX= 2 nm). In second derivative UV spectrophotometry d2A/dI2 values were measured at 252.84 nm in the second derivative UV spectra of the solution of FEX in methanol-water (1:1) in the range of 245 - 285 nm (AX= 2 nm). Linearity range was found as 100.0 - 1000.0 jjg/mL in all the spectrophotometric methods. Mean recoveries and the relative standard deviations of the methods were found as 99.55 % and 1.10 % in original UV spectrophotometry, 100.97 % and 1.09 % in first derivative UV spectrophotometry and, 99.25 % and 1.10 % in second derivative UV spectrophotometry respectively. In HPLC method, an isocratic system consisted of an ACE C18 analytical column and a mobile phase composed of methanol - phosphate buffer (pH 3.0, 0.1 M) (95:5, v/v) at a flow rate 1.0 mL/min was used for the optimal chromatographic separation using UV detection at 220 nm. Diflucortolone valerate was used as internal standard. Mean recoveries and the relative standard deviations was found as 100.23 % and 0.54 % in HPLC method. All the methods developed were successfully applied to five tablet formulations commercially available in Turkish drug market and the results were compared statistically with each other.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In present study, three new spectrophotometric methods, original UV spectrophotom etry, first and second order derivative UV spectrophotometry and a new HPLC method were developed for the determination of fexofenadine HCl (FEX) in pharmaceutical preparations. In original UV spectrophotometry, absorbances were measured at 258.7 nm in the zero order UV spectra of the solution of FEX in methanol-water (1:1) in the range of 220 - 290 nm. In first derivative UV spectrophotometry, dA/dl values were measured at 270.4 nm in the first derivative UV spectra of the solution of FEX in methanol-water (1:1) in the range of 245 - 285 nm (AX= 2 nm). In second derivative UV spectrophotometry d2A/dI2 values were measured at 252.84 nm in the second derivative UV spectra of the solution of FEX in methanol-water (1:1) in the range of 245 - 285 nm (AX= 2 nm). Linearity range was found as 100.0 - 1000.0 jjg/mL in all the spectrophotometric methods. Mean recoveries and the relative standard deviations of the methods were found as 99.55 % and 1.10 % in original UV spectrophotometry, 100.97 % and 1.09 % in first derivative UV spectrophotometry and, 99.25 % and 1.10 % in second derivative UV spectrophotometry respectively. In HPLC method, an isocratic system consisted of an ACE C18 analytical column and a mobile phase composed of methanol - phosphate buffer (pH 3.0, 0.1 M) (95:5, v/v) at a flow rate 1.0 mL/min was used for the optimal chromatographic separation using UV detection at 220 nm. Diflucortolone valerate was used as internal standard. Mean recoveries and the relative standard deviations was found as 100.23 % and 0.54 % in HPLC method. All the methods developed were successfully applied to five tablet formulations commercially available in Turkish drug market and the results were compared statistically with each other.

Key concepts: Spectrophotometry, Chemistry, Chromatography, Methanol, High-performance liquid chromatography, Derivative (finance), Analytical Chemistry (journal), Dosage form

Related papers

Back to paper searchBrowse research topicsOriginal source
Spectrophotometric and High Performance Liquid Chromatographic Determination of Fexofenadine Hydrochloride in Pharmaceutical Formulations — Research Paper | ScholarLens