IJESRTJOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Variation of Performance of Refrigeration System at different Temperature
Ankit Tiwari, Sachin Baraskar
Abstract
Ankit Tiwari, Sachin Baraskar
Abstract
In this paper, the performances of four ozone-friendly Hydrofluorocarbon (HFC) refrigerants (R125, R134a, R143a and R152a) selected to replace R12 in a vapour compression refrigeration system were investigated experimentally and compared. The performance in term of coefficient of performance (COP), refrigerating capacity (RC), and compressor work (We) were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The system performance increases as the evaporating temperature increases, but reduces as the condensing temperature increases. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapour compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Also, R152a offers the best desirable environmental requirements; zero Ozone Depleting Potential (ODP) and very low Global Warming Potential (GWP).
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this paper, the performances of four ozone-friendly Hydrofluorocarbon (HFC) refrigerants (R125, R134a, R143a and R152a) selected to replace R12 in a vapour compression refrigeration system were investigated experimentally and compared. The performance in term of coefficient of performance (COP), refrigerating capacity (RC), and compressor work (We) were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The system performance increases as the evaporating temperature increases, but reduces as the condensing temperature increases. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapour compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Also, R152a offers the best desirable environmental requirements; zero Ozone Depleting Potential (ODP) and very low Global Warming Potential (GWP).
Key concepts: Refrigerant, Refrigeration, Coefficient of performance, Vapor-compression refrigeration, Gas compressor, Cooling capacity, Global-warming potential, Work (physics)