2014Unpublished venueRequires access

IJESRTJOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Variation of Performance of Refrigeration System at different Temperature

Ankit Tiwari, Sachin Baraskar

Open publisher page 0 citations

Abstract

In this paper, the performances of four ozone-friendly Hydrofluorocarbon (HFC) refrigerants (R125, R134a, R143a and R152a) selected to replace R12 in a vapour compression refrigeration system were investigated experimentally and compared. The performance in term of coefficient of performance (COP), refrigerating capacity (RC), and compressor work (We) were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The system performance increases as the evaporating temperature increases, but reduces as the condensing temperature increases. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapour compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Also, R152a offers the best desirable environmental requirements; zero Ozone Depleting Potential (ODP) and very low Global Warming Potential (GWP).

About this research paper

What this paper is about

In this paper, the performances of four ozone-friendly Hydrofluorocarbon (HFC) refrigerants (R125, R134a, R143a and R152a) selected to replace R12 in a vapour compression refrigeration system were investigated experimentally and compared. The performance in term of coefficient of performance (COP), refrigerating capacity (RC), and compressor work (We) were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The system performance increases as the evaporating temperature increases, but reduces as the condensing temperature increases. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapour compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Also, R152a offers the best desirable environmental requirements; zero Ozone Depleting Potential (ODP) and very low Global Warming Potential (GWP).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, the performances of four ozone-friendly Hydrofluorocarbon (HFC) refrigerants (R125, R134a, R143a and R152a) selected to replace R12 in a vapour compression refrigeration system were investigated experimentally and compared. The performance in term of coefficient of performance (COP), refrigerating capacity (RC), and compressor work (We) were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The system performance increases as the evaporating temperature increases, but reduces as the condensing temperature increases. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapour compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Also, R152a offers the best desirable environmental requirements; zero Ozone Depleting Potential (ODP) and very low Global Warming Potential (GWP).

Key concepts: Refrigerant, Refrigeration, Coefficient of performance, Vapor-compression refrigeration, Gas compressor, Cooling capacity, Global-warming potential, Work (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
IJESRTJOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Variation of Performance of Refrigeration System at different Temperature — Research Paper | ScholarLens