Minimally invasive intervention for acute bleeding from a pseudoaneurysm after revision hip arthroplasty.
Benjamin Ulmar, Andrik J. Aschoff, Karl Heinz Orend, Wolfhart Puhl, Klaus Huch
Abstract
Benjamin Ulmar, Andrik J. Aschoff, Karl Heinz Orend, Wolfhart Puhl, Klaus Huch
Abstract
After multiple revisions of her right hip arthroplasty, an 83-year-old woman developed deep infection with a chronic draining sinus. In August 2002 severe acute bleeding occurred through this fistula. Angiography revealed a pseudoaneurysm of the right external iliac artery. Because of the multiple pathologies affecting this ASA grade IV patient, conventional surgical treatment was considered to be contra-indicated, and a stent was placed percutaneously under fluoroscopic control to seal the vascular laceration. No haematoma and no further bleeding was observed on the control CT-scan or at angiography. However the patient died with terminal renal failure forty days later. The case reported shows a rare complication of total hip arthroplasty. The method used in this case to seal the leakage, using a covered stent, is uncommon but effective in cases where conventional surgery is contra-indicated.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
After multiple revisions of her right hip arthroplasty, an 83-year-old woman developed deep infection with a chronic draining sinus. In August 2002 severe acute bleeding occurred through this fistula. Angiography revealed a pseudoaneurysm of the right external iliac artery. Because of the multiple pathologies affecting this ASA grade IV patient, conventional surgical treatment was considered to be contra-indicated, and a stent was placed percutaneously under fluoroscopic control to seal the vascular laceration. No haematoma and no further bleeding was observed on the control CT-scan or at angiography. However the patient died with terminal renal failure forty days later. The case reported shows a rare complication of total hip arthroplasty. The method used in this case to seal the leakage, using a covered stent, is uncommon but effective in cases where conventional surgery is contra-indicated.
Key concepts: Medicine, Pseudoaneurysm, Surgery, Angiography, Complication, Stent, Fistula, Radiology