Experiences from New Swedish Passive House Projects
Ulla Janson
Abstract
Ulla Janson
Abstract
ABSTRACT: In a Swedish research project carried out at Lund University, new Passive house projects are studied to see what knowledge and components that are necessary to get a more wide spread deployment of Passive houses in a cold climate. The Passive houses are closely followed; from the clients decision on building a Passive house, through the planning process, the building process, measurements of actual energy use after the tenants move in and the tenants ’ opinions on living in a Passive house. The results show a low need of energy for heating together with high indoor comfort. One investigated Passive house consumed 44 kWh/m2 per annum of district heating for heating and domestic hot water: a 72 % reduction comparison to Swedish averages 160 kWh/m2 per annum for heating and domestic hot water in multifamily houses. Knowledge among all building team participants about Passive houses is necessary to get a well functioning dwelling.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
ABSTRACT: In a Swedish research project carried out at Lund University, new Passive house projects are studied to see what knowledge and components that are necessary to get a more wide spread deployment of Passive houses in a cold climate. The Passive houses are closely followed; from the clients decision on building a Passive house, through the planning process, the building process, measurements of actual energy use after the tenants move in and the tenants ’ opinions on living in a Passive house. The results show a low need of energy for heating together with high indoor comfort. One investigated Passive house consumed 44 kWh/m2 per annum of district heating for heating and domestic hot water: a 72 % reduction comparison to Swedish averages 160 kWh/m2 per annum for heating and domestic hot water in multifamily houses. Knowledge among all building team participants about Passive houses is necessary to get a well functioning dwelling.
Key concepts: Passive house, Passive solar building design, Architectural engineering, Software deployment, Passive smoking, Living room, Low-energy house, Process (computing)