2011•International Journal of Fundamental Physical SciencesOpen access

The effect of operational parameters on the output power of copper vapor laser with small-bore tube

Saeid Behrouzinia, M. Zand, A. Namdar, A. Moghimi

Open full text 5 citations

Abstract

The effects of buffer gas pressure, electrical input power and pulse repetition frequency on the output power of 510.6- and 578.2nm transitions have been experimentally investigated in a copper vapor laser with small-bore tube (11mm of diameter and 580mm of length). It is observed that the output power characteristics are strongly influenced by these parameters. A maximum output power of laser is obtained at about 4W with 27 kHz of pulse repetition frequency, 30 torr of Ne buffer gas pressure and 1.42kW of electrical input power. The waveforms of the current, tube voltage and laser pulses have also been observed.

About this research paper

What this paper is about

The effects of buffer gas pressure, electrical input power and pulse repetition frequency on the output power of 510.6- and 578.2nm transitions have been experimentally investigated in a copper vapor laser with small-bore tube (11mm of diameter and 580mm of length). It is observed that the output power characteristics are strongly influenced by these parameters. A maximum output power of laser is obtained at about 4W with 27 kHz of pulse repetition frequency, 30 torr of Ne buffer gas pressure and 1.42kW of electrical input power. The waveforms of the current, tube voltage and laser pulses have also been observed.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effects of buffer gas pressure, electrical input power and pulse repetition frequency on the output power of 510.6- and 578.2nm transitions have been experimentally investigated in a copper vapor laser with small-bore tube (11mm of diameter and 580mm of length). It is observed that the output power characteristics are strongly influenced by these parameters. A maximum output power of laser is obtained at about 4W with 27 kHz of pulse repetition frequency, 30 torr of Ne buffer gas pressure and 1.42kW of electrical input power. The waveforms of the current, tube voltage and laser pulses have also been observed.

Key concepts: Torr, Copper vapor laser, Materials science, Laser, Buffer gas, Waveform, Power (physics), Tube (container)

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of operational parameters on the output power of copper vapor laser with small-bore tube — Research Paper | ScholarLens