Long-term radiographic evaluation of Trilock press-fit acetabular components in primary total hip arthroplasty.

Brett R. Levine, Russell D. Weisz, Erik N. Kubiak, Nicholas Testa

Open publisher page 4 citations

Abstract

A retrospective radiographic evaluation of 39 acetabulae reconstructed with Trilock press-fit components (Depuy, Warsaw, IN) without use of supplementary fixation was performed. The following radiographic criteria were evaluated: change in component inclination angle, migration, osteolytic areas, and radiolucent lines. Acetabular components were considered loose when there was migration greater than four millimeters, change in abduction angle greater than four degrees, or a concentric radiolucent line greater than two millimeters. The average length of follow-up was 12.6 years. Six of the 39 (15.4%) total hip arthroplasties were considered loose. Two (5.1%) of these were revised and four (10.4%) were asymptomatic at the time of latest follow-up. Significant areas of osteolysis were found in 15 hips (38.5%). We conclude that the Trilock acetabular component provides adequate fixation and satisfactory long-term results.

About this research paper

What this paper is about

A retrospective radiographic evaluation of 39 acetabulae reconstructed with Trilock press-fit components (Depuy, Warsaw, IN) without use of supplementary fixation was performed. The following radiographic criteria were evaluated: change in component inclination angle, migration, osteolytic areas, and radiolucent lines. Acetabular components were considered loose when there was migration greater than four millimeters, change in abduction angle greater than four degrees, or a concentric radiolucent line greater than two millimeters. The average length of follow-up was 12.6 years. Six of the 39 (15.4%) total hip arthroplasties were considered loose. Two (5.1%) of these were revised and four (10.4%) were asymptomatic at the time of latest follow-up. Significant areas of osteolysis were found in 15 hips (38.5%). We conclude that the Trilock acetabular component provides adequate fixation and satisfactory long-term results.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A retrospective radiographic evaluation of 39 acetabulae reconstructed with Trilock press-fit components (Depuy, Warsaw, IN) without use of supplementary fixation was performed. The following radiographic criteria were evaluated: change in component inclination angle, migration, osteolytic areas, and radiolucent lines. Acetabular components were considered loose when there was migration greater than four millimeters, change in abduction angle greater than four degrees, or a concentric radiolucent line greater than two millimeters. The average length of follow-up was 12.6 years. Six of the 39 (15.4%) total hip arthroplasties were considered loose. Two (5.1%) of these were revised and four (10.4%) were asymptomatic at the time of latest follow-up. Significant areas of osteolysis were found in 15 hips (38.5%). We conclude that the Trilock acetabular component provides adequate fixation and satisfactory long-term results.

Key concepts: Radiodensity, Medicine, Radiography, Osteolysis, Acetabulum, Total hip arthroplasty, Asymptomatic, Fixation (population genetics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Long-term radiographic evaluation of Trilock press-fit acetabular components in primary total hip arthroplasty. — Research Paper | ScholarLens