2012Unpublished venueRequires access

New Spectrophotometric Methods for Simultaneous Determination of Amlodipine besylate and Benazepril in Tablet Dosage Forms

Joshi Hv, Patel Jk

Open publisher page 0 citations

Abstract

Two simple, accurate, precise, reproducible, requiring no prior separation and economical procedures for simultaneous estimation of Amlodipine besylate (AML) and Benazepril (BEN) in tablet dosage form have been developed. The first method is simultaneous equation method; in this method 360.0 nm and 240.0 nm were selected to measure the absorbance of drugs at both wavelengths. The second method is Q-value analysis based on measurement of absorptivity at 227.50 nm (as an iso-absorptive point) and 360.0 nm at maximum wavelength of AML, 360.0 nm and at isoabsorptive point 227.50 nm both AML and BEN shows linearity in a concentration range of 5-40 µg/mL. Recovery studies range from >99.41% for AMD and >98.93% for BEN in case of simultaneous equation method and >100% for AMD and >99.55% for BEN in case of Q-analysis method confirming the accuracy of the proposed method. The proposed methods are recommended for routine analysis since it is rapid, simple, accurate and also sensitive and specific (no heating and no organic solvent extraction is required).

About this research paper

What this paper is about

Two simple, accurate, precise, reproducible, requiring no prior separation and economical procedures for simultaneous estimation of Amlodipine besylate (AML) and Benazepril (BEN) in tablet dosage form have been developed. The first method is simultaneous equation method; in this method 360.0 nm and 240.0 nm were selected to measure the absorbance of drugs at both wavelengths. The second method is Q-value analysis based on measurement of absorptivity at 227.50 nm (as an iso-absorptive point) and 360.0 nm at maximum wavelength of AML, 360.0 nm and at isoabsorptive point 227.50 nm both AML and BEN shows linearity in a concentration range of 5-40 µg/mL. Recovery studies range from >99.41% for AMD and >98.93% for BEN in case of simultaneous equation method and >100% for AMD and >99.55% for BEN in case of Q-analysis method confirming the accuracy of the proposed method. The proposed methods are recommended for routine analysis since it is rapid, simple, accurate and also sensitive and specific (no heating and no organic solvent extraction is required).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two simple, accurate, precise, reproducible, requiring no prior separation and economical procedures for simultaneous estimation of Amlodipine besylate (AML) and Benazepril (BEN) in tablet dosage form have been developed. The first method is simultaneous equation method; in this method 360.0 nm and 240.0 nm were selected to measure the absorbance of drugs at both wavelengths. The second method is Q-value analysis based on measurement of absorptivity at 227.50 nm (as an iso-absorptive point) and 360.0 nm at maximum wavelength of AML, 360.0 nm and at isoabsorptive point 227.50 nm both AML and BEN shows linearity in a concentration range of 5-40 µg/mL. Recovery studies range from >99.41% for AMD and >98.93% for BEN in case of simultaneous equation method and >100% for AMD and >99.55% for BEN in case of Q-analysis method confirming the accuracy of the proposed method. The proposed methods are recommended for routine analysis since it is rapid, simple, accurate and also sensitive and specific (no heating and no organic solvent extraction is required).

Key concepts: Amlodipine, Absorbance, Benazepril, Dosage form, Molar absorptivity, Chromatography, Materials science, Linearity

Related papers

Back to paper searchBrowse research topicsOriginal source
New Spectrophotometric Methods for Simultaneous Determination of Amlodipine besylate and Benazepril in Tablet Dosage Forms — Research Paper | ScholarLens