2016Pakistan Journal of Pharmaceutical SciencesOpen access

Single dose pharmacokinetics of atorvastatin oral formulations using a simple HPLC-UV method

Muhammad Sohail

Open full text 2 citations

Abstract

The study was aimed to assess pharmacokinetics of atorvastatin (40 mg) in healthy fasted human subjects by a simple and inexpensive high performance liquid chromatography. Experimental design of the study was a randomized, two way, two periods, crossover study (single dose in fasted conditions). Eighteen (18) healthy male volunteers were enrolled according to FDA guidelines. The plasma samples were assayed using an isocratic High Performance Liquid Chromatography (HPLC) system of Agilent technologies USA consisted of an isocratic pump with column of Thermo Electron Corporation USA (ODS hypersil C(18) 4.6 mm x 250 mm), a UV-visible detector set at λ(max) 237 nm. Maximum plasma concentrations (C(max)) of atorvastatin (Mean ± SEM) for the reference product (A) found to be 13.739±0.210ng/ml & 13.374±0.145ng/ml for test product (B). T(max) values (Mean±SEM) of atorvastatin were 1.222 ±0.060 hours and 1.167±0.057 hours for reference and test products, respectively. The values of AUC(0-oo) (Mean ± SEM) for the reference (A) and test product (B) were 73.955 ± 1.715ng.h/ml and 77.773 ± 1.858ng. h/ml, respectively. Other pharmacokinetic parameters of both products were also determined. A statistical non-significant difference between pharmacokinetic parameters has been found and both brands of atorvastatin showed the same rate and extent of absorption in healthy fasted human volunteers after single dose. A simple and cost effective HPLC method was developed and applied.

Open-access reader

About this research paper

What this paper is about

The study was aimed to assess pharmacokinetics of atorvastatin (40 mg) in healthy fasted human subjects by a simple and inexpensive high performance liquid chromatography. Experimental design of the study was a randomized, two way, two periods, crossover study (single dose in fasted conditions). Eighteen (18) healthy male volunteers were enrolled according to FDA guidelines. The plasma samples were assayed using an isocratic High Performance Liquid Chromatography (HPLC) system of Agilent technologies USA consisted of an isocratic pump with column of Thermo Electron Corporation USA (ODS hypersil C(18) 4.6 mm x 250 mm), a UV-visible detector set at λ(max) 237 nm. Maximum plasma concentrations (C(max)) of atorvastatin (Mean ± SEM) for the reference product (A) found to be 13.739±0.210ng/ml & 13.374±0.145ng/ml for test product (B). T(max) values (Mean±SEM) of atorvastatin were 1.222 ±0.060 hours and 1.167±0.057 hours for reference and test products, respectively. The values of AUC(0-oo) (Mean ± SEM) for the reference (A) and test product (B) were 73.955 ± 1.715ng.h/ml and 77.773 ± 1.858ng. h/ml, respectively. Other pharmacokinetic parameters of both products were also determined. A statistical non-significant difference between pharmacokinetic parameters has been found and both brands of atorvastatin showed the same rate and extent of absorption in healthy fasted human volunteers after single dose. A simple and cost effective HPLC method was developed and applied.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The study was aimed to assess pharmacokinetics of atorvastatin (40 mg) in healthy fasted human subjects by a simple and inexpensive high performance liquid chromatography. Experimental design of the study was a randomized, two way, two periods, crossover study (single dose in fasted conditions). Eighteen (18) healthy male volunteers were enrolled according to FDA guidelines. The plasma samples were assayed using an isocratic High Performance Liquid Chromatography (HPLC) system of Agilent technologies USA consisted of an isocratic pump with column of Thermo Electron Corporation USA (ODS hypersil C(18) 4.6 mm x 250 mm), a UV-visible detector set at λ(max) 237 nm. Maximum plasma concentrations (C(max)) of atorvastatin (Mean ± SEM) for the reference product (A) found to be 13.739±0.210ng/ml & 13.374±0.145ng/ml for test product (B). T(max) values (Mean±SEM) of atorvastatin were 1.222 ±0.060 hours and 1.167±0.057 hours for reference and test products, respectively. The values of AUC(0-oo) (Mean ± SEM) for the reference (A) and test product (B) were 73.955 ± 1.715ng.h/ml and 77.773 ± 1.858ng. h/ml, respectively. Other pharmacokinetic parameters of both products were also determined. A statistical non-significant difference between pharmacokinetic parameters has been found and both brands of atorvastatin showed the same rate and extent of absorption in healthy fasted human volunteers after single dose. A simple and cost effective HPLC method was developed and applied.

Key concepts: Atorvastatin, Pharmacokinetics, High-performance liquid chromatography, Chromatography, Crossover study, Chemistry, Oral administration, Pharmacology

Related papers

Back to paper searchBrowse research topicsOriginal source
Single dose pharmacokinetics of atorvastatin oral formulations using a simple HPLC-UV method — Research Paper | ScholarLens