Insulation Coordination for38kV Circuit Breakers

R. A. Fewand

Open publisher page 0 citations

Abstract

Based on a reviewoftheimpulse insulation requirements for38kVcircuit breakers andtheimpact of insulation coordination using modernarresters, a change is suggested inthewaytheimpulse requirements arestated for thecircuit breaker. Thefacets ofcircuit breaker design which may beaffected are indicated. Specifically itissuggested thatinthepresent stateoftheart, circuit breakers forgeneral application at34.5kVshould haveastandard requirement for 150kVBILphase toground, and200kVBILphase tophase andacrosstheopenbreak. Background Formanyyears200kVhasbeenstandard BILfor34.5 kVcircuit breakers. A 1950reference (1)gives theprotective characteristics ofarresters available atthattime.Manyofthe subtransmission circuits operating atapproximately 34.5kV were ungrounded, requiring theuse of100% or 37 kV arresters. Considering theprotective characteristics ofthe thenavailable arresters, 200kV BILwas required inthe circuit breaker inorderto assure coordination withthe arrester. Sincethattime, arresterprotective characteristics haveimproved substantially. Intheprocess ofdeveloping vacuum circuit breakers for 34.5kVservice, itbecameapparent that extrainsulation was being addedtothecircuit breaker simply tomeetthestandard requirement for200kVBIL.Itbecamequestionable whether this extrainsulation wouldhaveanybenefit fortheuserifthe breaker was to beapplied ina substation withmodern arresters. Thepurpose ofthis paperistoreview theinsulation coordination andprovide a basis forconsideration ofa more effective way ofspecifying theinsulation requirements for thecircuit breakers.

About this research paper

What this paper is about

Based on a reviewoftheimpulse insulation requirements for38kVcircuit breakers andtheimpact of insulation coordination using modernarresters, a change is suggested inthewaytheimpulse requirements arestated for thecircuit breaker. Thefacets ofcircuit breaker design which may beaffected are indicated. Specifically itissuggested thatinthepresent stateoftheart, circuit breakers forgeneral application at34.5kVshould haveastandard requirement for 150kVBILphase toground, and200kVBILphase tophase andacrosstheopenbreak. Background Formanyyears200kVhasbeenstandard BILfor34.5 kVcircuit breakers. A 1950reference (1)gives theprotective characteristics ofarresters available atthattime.Manyofthe subtransmission circuits operating atapproximately 34.5kV were ungrounded, requiring theuse of100% or 37 kV arresters. Considering theprotective characteristics ofthe thenavailable arresters, 200kV BILwas required inthe circuit breaker inorderto assure coordination withthe arrester. Sincethattime, arresterprotective characteristics haveimproved substantially. Intheprocess ofdeveloping vacuum circuit breakers for 34.5kVservice, itbecameapparent that extrainsulation was being addedtothecircuit breaker simply tomeetthestandard requirement for200kVBIL.Itbecamequestionable whether this extrainsulation wouldhaveanybenefit fortheuserifthe breaker was to beapplied ina substation withmodern arresters. Thepurpose ofthis paperistoreview theinsulation coordination andprovide a basis forconsideration ofa more effective way ofspecifying theinsulation requirements for thecircuit breakers.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on a reviewoftheimpulse insulation requirements for38kVcircuit breakers andtheimpact of insulation coordination using modernarresters, a change is suggested inthewaytheimpulse requirements arestated for thecircuit breaker. Thefacets ofcircuit breaker design which may beaffected are indicated. Specifically itissuggested thatinthepresent stateoftheart, circuit breakers forgeneral application at34.5kVshould haveastandard requirement for 150kVBILphase toground, and200kVBILphase tophase andacrosstheopenbreak. Background Formanyyears200kVhasbeenstandard BILfor34.5 kVcircuit breakers. A 1950reference (1)gives theprotective characteristics ofarresters available atthattime.Manyofthe subtransmission circuits operating atapproximately 34.5kV were ungrounded, requiring theuse of100% or 37 kV arresters. Considering theprotective characteristics ofthe thenavailable arresters, 200kV BILwas required inthe circuit breaker inorderto assure coordination withthe arrester. Sincethattime, arresterprotective characteristics haveimproved substantially. Intheprocess ofdeveloping vacuum circuit breakers for 34.5kVservice, itbecameapparent that extrainsulation was being addedtothecircuit breaker simply tomeetthestandard requirement for200kVBIL.Itbecamequestionable whether this extrainsulation wouldhaveanybenefit fortheuserifthe breaker was to beapplied ina substation withmodern arresters. Thepurpose ofthis paperistoreview theinsulation coordination andprovide a basis forconsideration ofa more effective way ofspecifying theinsulation requirements for thecircuit breakers.

Key concepts: Circuit breaker, Sulfur hexafluoride circuit breaker, Distribution board, Fuse (electrical), Engineering, Electrical engineering, Disconnector, Transient recovery voltage