2007Unpublished venueRequires access

Coupled Analytical Tool of Ventilation Calculation and CFD in Annexation System of Cool/Heat Tube and Natural Ventilation

Song Pan, Harunori Yoshida, Mingjie Zheng

Open publisher page 0 citations

Abstract

Natural ventilation airflow rate is generally calculated using indoor and outdoor temperature difference without consideration of heat balance based on the vertical air temperature distribution in simple analytical method. However, room air temperature is influenced by natural ventilation airflow rate, and airflow rate is influenced by room air temperature, so it is necessary to perform a coupled analysis taking into account both heat balance and ventilation to obtain the correct result. Moreover, when there is marked indoor vertical temperature distribution, as found in large enclosures, or when ventilation airflow rate is small, significant computation error will occur if the set value of room air temperature differs greatly from the actual value. To solve two problems mentioned above, the authors developed a natural ventilation tool that takes into account indoor vertical temperature distribution and proposed a coupled simulation method using this tool in conjunction with CFD to simultaneously calculate indoor air flow/temperature distribution and natural ventilation airflow rate. In this paper, the difference between this method and the simple analytical method was shown clearly by comparing calculation results of the two methods about an actual annexation system of cool/heat tube and natural ventilation in a gymnasium. KEYWORDS cool/heat tube, natural ventilation, coupled analytical tool with natural ventilation and CFD

About this research paper

What this paper is about

Natural ventilation airflow rate is generally calculated using indoor and outdoor temperature difference without consideration of heat balance based on the vertical air temperature distribution in simple analytical method. However, room air temperature is influenced by natural ventilation airflow rate, and airflow rate is influenced by room air temperature, so it is necessary to perform a coupled analysis taking into account both heat balance and ventilation to obtain the correct result. Moreover, when there is marked indoor vertical temperature distribution, as found in large enclosures, or when ventilation airflow rate is small, significant computation error will occur if the set value of room air temperature differs greatly from the actual value. To solve two problems mentioned above, the authors developed a natural ventilation tool that takes into account indoor vertical temperature distribution and proposed a coupled simulation method using this tool in conjunction with CFD to simultaneously calculate indoor air flow/temperature distribution and natural ventilation airflow rate. In this paper, the difference between this method and the simple analytical method was shown clearly by comparing calculation results of the two methods about an actual annexation system of cool/heat tube and natural ventilation in a gymnasium. KEYWORDS cool/heat tube, natural ventilation, coupled analytical tool with natural ventilation and CFD

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Natural ventilation airflow rate is generally calculated using indoor and outdoor temperature difference without consideration of heat balance based on the vertical air temperature distribution in simple analytical method. However, room air temperature is influenced by natural ventilation airflow rate, and airflow rate is influenced by room air temperature, so it is necessary to perform a coupled analysis taking into account both heat balance and ventilation to obtain the correct result. Moreover, when there is marked indoor vertical temperature distribution, as found in large enclosures, or when ventilation airflow rate is small, significant computation error will occur if the set value of room air temperature differs greatly from the actual value. To solve two problems mentioned above, the authors developed a natural ventilation tool that takes into account indoor vertical temperature distribution and proposed a coupled simulation method using this tool in conjunction with CFD to simultaneously calculate indoor air flow/temperature distribution and natural ventilation airflow rate. In this paper, the difference between this method and the simple analytical method was shown clearly by comparing calculation results of the two methods about an actual annexation system of cool/heat tube and natural ventilation in a gymnasium. KEYWORDS cool/heat tube, natural ventilation, coupled analytical tool with natural ventilation and CFD

Key concepts: Airflow, Natural ventilation, Ventilation (architecture), Computational fluid dynamics, Environmental science, Mechanics, Meteorology, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Coupled Analytical Tool of Ventilation Calculation and CFD in Annexation System of Cool/Heat Tube and Natural Ventilation — Research Paper | ScholarLens