EFFECTS OF SEISMIC RETROFITTING ON REINFORCED CONCRETE BUILDINGS SUFFERED DURING THE 2004 MID NIIGATA PREFECTURE EARTHQUAKE

Yoshimasa Honda, Daisuke Kato, Yukiko Nakamura

Open publisher page 0 citations

Abstract

This study reports on the relation between seismic performance and damage of buildings during the 2004 Mid Niigata Prefecture Earthquake. Two buildings under construction for retrofitting were studied. One of them had light damage, another had negligible damage. A building with light damage had four columns with damage level of Ⅳ during the Earthquake. And the remaining seismic performance of the building was 89 %. Evaluated seismic performance index (Is value) of the long span direction of the building was 0.58~0.79. The lack of seismic performance was assumed to be a cause of the damage on the building. On the other hand the Is value of another building was 0.44~0.71 although the damage of the building was negligible. Finally the effect of the seismic retrofitting for two buildings was discussed comparing the relationship between damage level and the seismic performance indices which varied depending the retrofitting process.

About this research paper

What this paper is about

This study reports on the relation between seismic performance and damage of buildings during the 2004 Mid Niigata Prefecture Earthquake. Two buildings under construction for retrofitting were studied. One of them had light damage, another had negligible damage. A building with light damage had four columns with damage level of Ⅳ during the Earthquake. And the remaining seismic performance of the building was 89 %. Evaluated seismic performance index (Is value) of the long span direction of the building was 0.58~0.79. The lack of seismic performance was assumed to be a cause of the damage on the building. On the other hand the Is value of another building was 0.44~0.71 although the damage of the building was negligible. Finally the effect of the seismic retrofitting for two buildings was discussed comparing the relationship between damage level and the seismic performance indices which varied depending the retrofitting process.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study reports on the relation between seismic performance and damage of buildings during the 2004 Mid Niigata Prefecture Earthquake. Two buildings under construction for retrofitting were studied. One of them had light damage, another had negligible damage. A building with light damage had four columns with damage level of Ⅳ during the Earthquake. And the remaining seismic performance of the building was 89 %. Evaluated seismic performance index (Is value) of the long span direction of the building was 0.58~0.79. The lack of seismic performance was assumed to be a cause of the damage on the building. On the other hand the Is value of another building was 0.44~0.71 although the damage of the building was negligible. Finally the effect of the seismic retrofitting for two buildings was discussed comparing the relationship between damage level and the seismic performance indices which varied depending the retrofitting process.

Key concepts: Retrofitting, Seismic retrofit, Seismic zone, Geology, Reinforced concrete, Seismology, Geotechnical engineering, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
EFFECTS OF SEISMIC RETROFITTING ON REINFORCED CONCRETE BUILDINGS SUFFERED DURING THE 2004 MID NIIGATA PREFECTURE EARTHQUAKE — Research Paper | ScholarLens