Osteoporosis is a disease that influences the quality of bone tissue. At present, osteoporosis represents a contraindication or a risk factor for osseointegration. The aim of this report was to evaluate the bone-to-implant contact of 2 loaded implants retrieved after prosthetic failure in a woman with type 1 osteoporosis. Histologically, only one implant was osseointegrated, and it appeared surrounded by healthy bone tissue. The bone-to-implant contact presented a mean of 51.25%. No foreign body reaction was found at the bone-to-implant contact, although epithelial downgrowth was observed at the interface. Data from this case report demonstrate that the peri-implant bone histology of the dental implant retrieved from an osteoporotic patient presented no alteration. However, the role of osteoporosis in the long-term success of dental implants needs further investigation.
OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Osteoporosis is a disease that influences the quality of bone tissue. At present, osteoporosis represents a contraindication or a risk factor for osseointegration. The aim of this report was to evaluate the bone-to-implant contact of 2 loaded implants retrieved after prosthetic failure in a woman with type 1 osteoporosis. Histologically, only one implant was osseointegrated, and it appeared surrounded by healthy bone tissue. The bone-to-implant contact presented a mean of 51.25%. No foreign body reaction was found at the bone-to-implant contact, although epithelial downgrowth was observed at the interface. Data from this case report demonstrate that the peri-implant bone histology of the dental implant retrieved from an osteoporotic patient presented no alteration. However, the role of osteoporosis in the long-term success of dental implants needs further investigation.
Key concepts: Osseointegration, Medicine, Contraindication, Implant, Osteoporosis, Dentistry, Dental implant, Implant failure