2002•IEEE Transactions on Nuclear ScienceRequires access

CdTe stacked detectors for gamma-ray detection

Shin Watanabe, Tadayuki Takahashi, Yuu Okada, G. Sato, M. Kouda, Takefumi Mitani, Y. Kobayashi, Kazuhiro Nakazawa, Yoshihiro Kuroda, M. Onishi

Open publisher page 27 citations

Abstract

We describe a stacked detector made of thin cadmium telluride (CdTe) diode detectors. By using a thin CdTe device, we can overcome the charge loss problem due to the small mobility and short lifetime of holes in CdTe or cadmium zinc telluride (CdZnTe) detectors. However, a CdTe detector with a thickness of more than 5 mm is needed for adequate detection efficiency for gamma-rays of several hundred keV. Good energy resolution and good peak detection efficiency are difficult to obtain using such a thick CdTe detector. The stacked detector enabled us to realize a detector with both high-energy resolution and good efficiencies for gamma rays up to several hundred keV. In order to verify this concept, we constructed a prototype made of ten layers of a 0.5-mm-thick CdTe diode detectors with a surface area of 21.5 mm/spl times/21.5 mm. With this, we have achieved 5.3-keV and 7.9-keV energy resolution [full width at half maximum (FWHM)] at 356 keV and 662 keV, respectively, at the temperature of -20/spl deg/C.

About this research paper

What this paper is about

We describe a stacked detector made of thin cadmium telluride (CdTe) diode detectors. By using a thin CdTe device, we can overcome the charge loss problem due to the small mobility and short lifetime of holes in CdTe or cadmium zinc telluride (CdZnTe) detectors. However, a CdTe detector with a thickness of more than 5 mm is needed for adequate detection efficiency for gamma-rays of several hundred keV. Good energy resolution and good peak detection efficiency are difficult to obtain using such a thick CdTe detector. The stacked detector enabled us to realize a detector with both high-energy resolution and good efficiencies for gamma rays up to several hundred keV. In order to verify this concept, we constructed a prototype made of ten layers of a 0.5-mm-thick CdTe diode detectors with a surface area of 21.5 mm/spl times/21.5 mm. With this, we have achieved 5.3-keV and 7.9-keV energy resolution [full width at half maximum (FWHM)] at 356 keV and 662 keV, respectively, at the temperature of -20/spl deg/C.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We describe a stacked detector made of thin cadmium telluride (CdTe) diode detectors. By using a thin CdTe device, we can overcome the charge loss problem due to the small mobility and short lifetime of holes in CdTe or cadmium zinc telluride (CdZnTe) detectors. However, a CdTe detector with a thickness of more than 5 mm is needed for adequate detection efficiency for gamma-rays of several hundred keV. Good energy resolution and good peak detection efficiency are difficult to obtain using such a thick CdTe detector. The stacked detector enabled us to realize a detector with both high-energy resolution and good efficiencies for gamma rays up to several hundred keV. In order to verify this concept, we constructed a prototype made of ten layers of a 0.5-mm-thick CdTe diode detectors with a surface area of 21.5 mm/spl times/21.5 mm. With this, we have achieved 5.3-keV and 7.9-keV energy resolution [full width at half maximum (FWHM)] at 356 keV and 662 keV, respectively, at the temperature of -20/spl deg/C.

Key concepts: Cadmium zinc telluride, Cadmium telluride photovoltaics, Detector, Full width at half maximum, Optoelectronics, X-ray detector, Particle detector, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
CdTe stacked detectors for gamma-ray detection — Research Paper | ScholarLens