1983Journal of Applied PhysiologyRequires access

Optimizing the exercise protocol for cardiopulmonary assessment

Mark J. Buchfuhrer, James E. Hansen, Terry E. Robinson, Darryl Y. Sue, Karlman Wasserman, Brian J. Whipp

Open publisher page 872 citations

Abstract

Twelve normal men performed 1-min incremental exercise tests to exhaustion in approximately 10 min on both treadmill and cycle ergometer. The maximal O2 uptake (VO2 max) and anaerobic threshold (AT) were higher (6 and 13%, respectively) on the treadmill than the cycle; the AT was reached at about 50% of VO2 max on both ergometers. Maximal CO2 output, heart rate, and O2 pulse were also slightly, but significantly higher on the treadmill. Maximal ventilation, gas exchange ratio, and ventilatory equivalents for O2 and CO2 for both forms of exercise were not significantly different. To determine the optimum exercise test for both treadmill and cycle, we exercised five of the subjects at various work rate increments on both ergometers in a randomized design. The treadmill increments were 0.8, 1.7, 2.5, and 4.2%/min at a constant speed of 3.4 mph, and 1.7 and 4.2%/min at 4.5 mph. Cycle increments were 15, 30, and 60 W/min. The VO2 max was significantly higher on tests where the increment magnitude was large enough to induce test durations of 8-17 min, but the AT was independent of test duration. Thus, for evaluating cardiopulmonary function with incremental exercise testing by either treadmill or cycle, we suggest selecting a work rate increment to bring the subject to the limit of his tolerance in about 10 min.

About this research paper

What this paper is about

Twelve normal men performed 1-min incremental exercise tests to exhaustion in approximately 10 min on both treadmill and cycle ergometer. The maximal O2 uptake (VO2 max) and anaerobic threshold (AT) were higher (6 and 13%, respectively) on the treadmill than the cycle; the AT was reached at about 50% of VO2 max on both ergometers. Maximal CO2 output, heart rate, and O2 pulse were also slightly, but significantly higher on the treadmill. Maximal ventilation, gas exchange ratio, and ventilatory equivalents for O2 and CO2 for both forms of exercise were not significantly different. To determine the optimum exercise test for both treadmill and cycle, we exercised five of the subjects at various work rate increments on both ergometers in a randomized design. The treadmill increments were 0.8, 1.7, 2.5, and 4.2%/min at a constant speed of 3.4 mph, and 1.7 and 4.2%/min at 4.5 mph. Cycle increments were 15, 30, and 60 W/min. The VO2 max was significantly higher on tests where the increment magnitude was large enough to induce test durations of 8-17 min, but the AT was independent of test duration. Thus, for evaluating cardiopulmonary function with incremental exercise testing by either treadmill or cycle, we suggest selecting a work rate increment to bring the subject to the limit of his tolerance in about 10 min.

Why it matters

OpenAlex reports 872 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Twelve normal men performed 1-min incremental exercise tests to exhaustion in approximately 10 min on both treadmill and cycle ergometer. The maximal O2 uptake (VO2 max) and anaerobic threshold (AT) were higher (6 and 13%, respectively) on the treadmill than the cycle; the AT was reached at about 50% of VO2 max on both ergometers. Maximal CO2 output, heart rate, and O2 pulse were also slightly, but significantly higher on the treadmill. Maximal ventilation, gas exchange ratio, and ventilatory equivalents for O2 and CO2 for both forms of exercise were not significantly different. To determine the optimum exercise test for both treadmill and cycle, we exercised five of the subjects at various work rate increments on both ergometers in a randomized design. The treadmill increments were 0.8, 1.7, 2.5, and 4.2%/min at a constant speed of 3.4 mph, and 1.7 and 4.2%/min at 4.5 mph. Cycle increments were 15, 30, and 60 W/min. The VO2 max was significantly higher on tests where the increment magnitude was large enough to induce test durations of 8-17 min, but the AT was independent of test duration. Thus, for evaluating cardiopulmonary function with incremental exercise testing by either treadmill or cycle, we suggest selecting a work rate increment to bring the subject to the limit of his tolerance in about 10 min.

Key concepts: Treadmill, Anaerobic exercise, Respiratory exchange ratio, Incremental exercise, Cycle ergometer, Work rate, VO2 max, Heart rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimizing the exercise protocol for cardiopulmonary assessment — Research Paper | ScholarLens