Effect of High Oxygen Concentrations on Nitrification and Performance of High-Purity Oxygen A/O Biofilm Process
Am Jang, In S. Kim
Abstract
Am Jang, In S. Kim
Abstract
A respirometric method has shown that the dissolved oxygen (DO) concentration has an effect on the growth rate of nitrifying micro-organisms. Oxygen uptake rates were normal at DO concentrations of 5 to 15 mg/L, but at 15 mg/L and greater, oxygen uptake was reduced, and these DO levels may be toxic to the nitrifying micro-organisms. The anoxic/aerobic (A/O)-high purity oxygen submerged biofilm process was tested using synthetic wastewater influent. Four different internal recycle ratios (R), that is, R = 0.5, 1.0, 1.5, and 2.0, were tested at 0.64 kg COD/m3-day and 0.14 kg NH4+-N/m3-day for the aerobic reactor. When R was increased, the removal efficiency of COD and total Kjeldhal nitrogen (TKN) also increased to greater than 90%. The efficiency of total nitrogen (TN) removal, however, was not proportional to the R. DO concentrations in the aerobic reactor were set at 5 and 10 mg/L to evaluate the effect of DO concentrations on the nitrification reaction. A COD removal efficiency of greaer than 90% was always achieved regardless of the DO concentration when the process aerobic reactor was operated in the range of 1.12 kg COD/m3-day and 0.21 kg NH4+-N/m3-day. The nitrification rate, however, changed significantly according to the DO concentration.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A respirometric method has shown that the dissolved oxygen (DO) concentration has an effect on the growth rate of nitrifying micro-organisms. Oxygen uptake rates were normal at DO concentrations of 5 to 15 mg/L, but at 15 mg/L and greater, oxygen uptake was reduced, and these DO levels may be toxic to the nitrifying micro-organisms. The anoxic/aerobic (A/O)-high purity oxygen submerged biofilm process was tested using synthetic wastewater influent. Four different internal recycle ratios (R), that is, R = 0.5, 1.0, 1.5, and 2.0, were tested at 0.64 kg COD/m3-day and 0.14 kg NH4+-N/m3-day for the aerobic reactor. When R was increased, the removal efficiency of COD and total Kjeldhal nitrogen (TKN) also increased to greater than 90%. The efficiency of total nitrogen (TN) removal, however, was not proportional to the R. DO concentrations in the aerobic reactor were set at 5 and 10 mg/L to evaluate the effect of DO concentrations on the nitrification reaction. A COD removal efficiency of greaer than 90% was always achieved regardless of the DO concentration when the process aerobic reactor was operated in the range of 1.12 kg COD/m3-day and 0.21 kg NH4+-N/m3-day. The nitrification rate, however, changed significantly according to the DO concentration.
Key concepts: Nitrification, Chemistry, Oxygen, Anoxic waters, Wastewater, Nitrogen, Aeration, Environmental chemistry