2015Textile Research JournalRequires access

Trunk marker sets and the subsequent calculation of trunk and breast kinematics during treadmill running

Chris Mills, Amy Loveridge, Alexandra Milligan, Joanna Scurr

Open publisher page 21 citations

Abstract

Female participants present a unique challenge as the design of the bra used to support the breasts occludes the correct positioning of many recommended trunk marker sets. This study aimed to compare the effect of two existing and one new trunk marker set on the calculation of trunk and breast kinematics. Twelve females had markers placed on their trunk and right nipple; these markers were tracked using infrared cameras during five running gait cycles and used to define three trunk calculation methods: Trunk 1: suprasternal notch, right and left ribs; Trunk 2: supersternal notch, processus xiphoideus, 7th cervical and 8th thoracic spinous process; Trunk 3: Trunk 2 plus a marker 33% from the suprasternal notch to the processus xiphoideus, and another 50% between the 7th cervical and 8th thoracic spinous process. Trunk segment capture success, segment origin instability, segmental residual, trunk kinematics, and breast range of motion (relative to the trunk segment), were calculated for each trunk segment. Segment capture success varied from 88% (Trunk 1) to 100% (Trunk 2 and 3). Segment origin instability ranged from 0.2 cm (Trunk 2 and 3) to 1.5 cm (Trunk 1). Maximum trunk extension differed by 7° and breast range of motion varied by 41% (anterioposterior), 54% (mediolateral), and 21% (superioinferior) between trunk calculation methods. The selection of marker set used to construct the trunk segment is critical before recommending improvements to bra design to improve breast support. The Trunk 3 marker set is recommended for subsequent breast research.

About this research paper

What this paper is about

Female participants present a unique challenge as the design of the bra used to support the breasts occludes the correct positioning of many recommended trunk marker sets. This study aimed to compare the effect of two existing and one new trunk marker set on the calculation of trunk and breast kinematics. Twelve females had markers placed on their trunk and right nipple; these markers were tracked using infrared cameras during five running gait cycles and used to define three trunk calculation methods: Trunk 1: suprasternal notch, right and left ribs; Trunk 2: supersternal notch, processus xiphoideus, 7th cervical and 8th thoracic spinous process; Trunk 3: Trunk 2 plus a marker 33% from the suprasternal notch to the processus xiphoideus, and another 50% between the 7th cervical and 8th thoracic spinous process. Trunk segment capture success, segment origin instability, segmental residual, trunk kinematics, and breast range of motion (relative to the trunk segment), were calculated for each trunk segment. Segment capture success varied from 88% (Trunk 1) to 100% (Trunk 2 and 3). Segment origin instability ranged from 0.2 cm (Trunk 2 and 3) to 1.5 cm (Trunk 1). Maximum trunk extension differed by 7° and breast range of motion varied by 41% (anterioposterior), 54% (mediolateral), and 21% (superioinferior) between trunk calculation methods. The selection of marker set used to construct the trunk segment is critical before recommending improvements to bra design to improve breast support. The Trunk 3 marker set is recommended for subsequent breast research.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Female participants present a unique challenge as the design of the bra used to support the breasts occludes the correct positioning of many recommended trunk marker sets. This study aimed to compare the effect of two existing and one new trunk marker set on the calculation of trunk and breast kinematics. Twelve females had markers placed on their trunk and right nipple; these markers were tracked using infrared cameras during five running gait cycles and used to define three trunk calculation methods: Trunk 1: suprasternal notch, right and left ribs; Trunk 2: supersternal notch, processus xiphoideus, 7th cervical and 8th thoracic spinous process; Trunk 3: Trunk 2 plus a marker 33% from the suprasternal notch to the processus xiphoideus, and another 50% between the 7th cervical and 8th thoracic spinous process. Trunk segment capture success, segment origin instability, segmental residual, trunk kinematics, and breast range of motion (relative to the trunk segment), were calculated for each trunk segment. Segment capture success varied from 88% (Trunk 1) to 100% (Trunk 2 and 3). Segment origin instability ranged from 0.2 cm (Trunk 2 and 3) to 1.5 cm (Trunk 1). Maximum trunk extension differed by 7° and breast range of motion varied by 41% (anterioposterior), 54% (mediolateral), and 21% (superioinferior) between trunk calculation methods. The selection of marker set used to construct the trunk segment is critical before recommending improvements to bra design to improve breast support. The Trunk 3 marker set is recommended for subsequent breast research.

Key concepts: Trunk, Torso, Kinematics, Anatomy, Medicine, Physical medicine and rehabilitation, Biology, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Trunk marker sets and the subsequent calculation of trunk and breast kinematics during treadmill running — Research Paper | ScholarLens