2015BioMed Research InternationalOpen access

Surgical Modification of the Murine Calvaria Osteolysis Model

Ali Mohammed Al-quhali, Yu Sun, Xizhuang Bai, Zhe Wu Jin, Guibo Yu

Open full text 3 citations

Abstract

The murine calvaria model has been adopted for evaluation of osteolysis and inflammation induced by polyethylene (PE) or metal wear debris. However, this model suffers from several complications. The purpose of our study is to introduce a surgical modification with lower complication rates, thus providing more accurate results. Forty C57/BL6 mice were divided into two groups, both receiving polyethylene particles. Surgical modifications were performed in group 1, and group 2 underwent traditional surgeries. The incidence of fluid leakage was recorded on the operative day. Curst formation, wound dehiscence, and bone exposure were recorded on day 7. Histological osteolysis was demonstrated by HE staining of tissue slices. Micro-CT was used for quantifying evaluation of osteolysis in two groups. Intraoperative fluid leakage was significantly reduced in group 1. Postoperative crust formation, wound dehiscence, and bone exposure were also significantly decreased in group 1. HE staining results revealed obvious osteolysis in group 1 and more obvious osteolysis in group 2. Bone volume fraction (BVF) was (0.32 ± 0.03) in group 1 compared to group 2 (0.24 ± 0.05). Bone mineral density (BMD) was (1.11 ± 0.03) in group 1 compared to group 2 (1.01 ± 0.02). Surgical modifications provide a reliable way for establishment of the murine calvaria osteolysis model.

Open-access reader

About this research paper

What this paper is about

The murine calvaria model has been adopted for evaluation of osteolysis and inflammation induced by polyethylene (PE) or metal wear debris. However, this model suffers from several complications. The purpose of our study is to introduce a surgical modification with lower complication rates, thus providing more accurate results. Forty C57/BL6 mice were divided into two groups, both receiving polyethylene particles. Surgical modifications were performed in group 1, and group 2 underwent traditional surgeries. The incidence of fluid leakage was recorded on the operative day. Curst formation, wound dehiscence, and bone exposure were recorded on day 7. Histological osteolysis was demonstrated by HE staining of tissue slices. Micro-CT was used for quantifying evaluation of osteolysis in two groups. Intraoperative fluid leakage was significantly reduced in group 1. Postoperative crust formation, wound dehiscence, and bone exposure were also significantly decreased in group 1. HE staining results revealed obvious osteolysis in group 1 and more obvious osteolysis in group 2. Bone volume fraction (BVF) was (0.32 ± 0.03) in group 1 compared to group 2 (0.24 ± 0.05). Bone mineral density (BMD) was (1.11 ± 0.03) in group 1 compared to group 2 (1.01 ± 0.02). Surgical modifications provide a reliable way for establishment of the murine calvaria osteolysis model.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The murine calvaria model has been adopted for evaluation of osteolysis and inflammation induced by polyethylene (PE) or metal wear debris. However, this model suffers from several complications. The purpose of our study is to introduce a surgical modification with lower complication rates, thus providing more accurate results. Forty C57/BL6 mice were divided into two groups, both receiving polyethylene particles. Surgical modifications were performed in group 1, and group 2 underwent traditional surgeries. The incidence of fluid leakage was recorded on the operative day. Curst formation, wound dehiscence, and bone exposure were recorded on day 7. Histological osteolysis was demonstrated by HE staining of tissue slices. Micro-CT was used for quantifying evaluation of osteolysis in two groups. Intraoperative fluid leakage was significantly reduced in group 1. Postoperative crust formation, wound dehiscence, and bone exposure were also significantly decreased in group 1. HE staining results revealed obvious osteolysis in group 1 and more obvious osteolysis in group 2. Bone volume fraction (BVF) was (0.32 ± 0.03) in group 1 compared to group 2 (0.24 ± 0.05). Bone mineral density (BMD) was (1.11 ± 0.03) in group 1 compared to group 2 (1.01 ± 0.02). Surgical modifications provide a reliable way for establishment of the murine calvaria osteolysis model.

Key concepts: Osteolysis, Calvaria, Medicine, Wound dehiscence, Dehiscence, Surgery, Urology, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Surgical Modification of the Murine Calvaria Osteolysis Model — Research Paper | ScholarLens