2004Journal of Electron MicroscopyRequires access

Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling

Hirokazu Sasaki

Open publisher page 41 citations

Abstract

We have developed a focused ion beam (FIB)-Ar ion-milling technique for high-resolution transmission electron microscopy. A micrometresized specimen was mounted on a cross section of metal foil of a few micrometres thick, using FIB microsampling. Following this, a 2 degrees wedgeshaped part was made in the specimen using FIB. Finally, the specimen was milled using an Ar ion beam to remove the FIB-damaged layers. We applied the FIB-Ar ion milling technique to a CeO(2)/Gd(2)Zr(2)O(7) multilayer specimen, resulting in the crystal lattice fringes of both layers being clearly observable in comparison to a specimen finished using a Ga ion beam at an accelerating voltage of 10 kV.

About this research paper

What this paper is about

We have developed a focused ion beam (FIB)-Ar ion-milling technique for high-resolution transmission electron microscopy. A micrometresized specimen was mounted on a cross section of metal foil of a few micrometres thick, using FIB microsampling. Following this, a 2 degrees wedgeshaped part was made in the specimen using FIB. Finally, the specimen was milled using an Ar ion beam to remove the FIB-damaged layers. We applied the FIB-Ar ion milling technique to a CeO(2)/Gd(2)Zr(2)O(7) multilayer specimen, resulting in the crystal lattice fringes of both layers being clearly observable in comparison to a specimen finished using a Ga ion beam at an accelerating voltage of 10 kV.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have developed a focused ion beam (FIB)-Ar ion-milling technique for high-resolution transmission electron microscopy. A micrometresized specimen was mounted on a cross section of metal foil of a few micrometres thick, using FIB microsampling. Following this, a 2 degrees wedgeshaped part was made in the specimen using FIB. Finally, the specimen was milled using an Ar ion beam to remove the FIB-damaged layers. We applied the FIB-Ar ion milling technique to a CeO(2)/Gd(2)Zr(2)O(7) multilayer specimen, resulting in the crystal lattice fringes of both layers being clearly observable in comparison to a specimen finished using a Ga ion beam at an accelerating voltage of 10 kV.

Key concepts: Focused ion beam, Materials science, Ion milling machine, Transmission electron microscopy, Ion beam, Ion, Acceleration voltage, FOIL method

Related papers

Back to paper searchBrowse research topicsOriginal source
Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling — Research Paper | ScholarLens