2014Vascular Specialist InternationalOpen access

Use of Reversed Iliac Leg Stent-Graft for the Treatment of Isolated Aneurysm of Internal Iliac Artery

Kyung Sup Song, Hyunsil Lee, Deok Ho Nam, Ki Hyuk Park, Sang Seob Yun, Bae Young Lee, Kang Hoon Lee

Open full text 5 citations

Abstract

This is to report the technique of reversed iliac leg stent-graft in endovascular treatment for isolated internal iliac artery (IIA) aneurysm, which had significant size discrepancy between the common iliac artery (CIA) and external iliac artery (EIA) in 3 patients from different hospitals. Three patients were a 85- and two 82-year-old men. Treated were right IIA aneurysms, sized 6.5×6.2 cm, 5.0×4.0 cm, and 4.1 cm in longest diameter, respectively. The diameters of the right CIA and right EIA measured 21 mm/11 mm, 15 mm/11 mm, and 20 mm/10 mm, respectively. In all cases, reversed iliac leg stent-grafts were prepared on-site; unsheathed and mounted upside-down manually, and deployed in each right CIA. Post-stent-graft angiograms showed complete exclusion of the aneurysms, except for minimal type 1 endoleak in one case. This technique is a useful treatment option in patients with isolated IIA aneurysm.

About this research paper

What this paper is about

This is to report the technique of reversed iliac leg stent-graft in endovascular treatment for isolated internal iliac artery (IIA) aneurysm, which had significant size discrepancy between the common iliac artery (CIA) and external iliac artery (EIA) in 3 patients from different hospitals. Three patients were a 85- and two 82-year-old men. Treated were right IIA aneurysms, sized 6.5×6.2 cm, 5.0×4.0 cm, and 4.1 cm in longest diameter, respectively. The diameters of the right CIA and right EIA measured 21 mm/11 mm, 15 mm/11 mm, and 20 mm/10 mm, respectively. In all cases, reversed iliac leg stent-grafts were prepared on-site; unsheathed and mounted upside-down manually, and deployed in each right CIA. Post-stent-graft angiograms showed complete exclusion of the aneurysms, except for minimal type 1 endoleak in one case. This technique is a useful treatment option in patients with isolated IIA aneurysm.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This is to report the technique of reversed iliac leg stent-graft in endovascular treatment for isolated internal iliac artery (IIA) aneurysm, which had significant size discrepancy between the common iliac artery (CIA) and external iliac artery (EIA) in 3 patients from different hospitals. Three patients were a 85- and two 82-year-old men. Treated were right IIA aneurysms, sized 6.5×6.2 cm, 5.0×4.0 cm, and 4.1 cm in longest diameter, respectively. The diameters of the right CIA and right EIA measured 21 mm/11 mm, 15 mm/11 mm, and 20 mm/10 mm, respectively. In all cases, reversed iliac leg stent-grafts were prepared on-site; unsheathed and mounted upside-down manually, and deployed in each right CIA. Post-stent-graft angiograms showed complete exclusion of the aneurysms, except for minimal type 1 endoleak in one case. This technique is a useful treatment option in patients with isolated IIA aneurysm.

Key concepts: Medicine, Common iliac artery, Aneurysm, Internal iliac artery, Stent, Iliac artery, Surgery, External iliac artery

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of Reversed Iliac Leg Stent-Graft for the Treatment of Isolated Aneurysm of Internal Iliac Artery — Research Paper | ScholarLens