2009Unpublished venueRequires access

Measurements of the Induced Power in a Shape Shifting Transmission Line According to Immunity Tests in Reverberation and Semi Anechoic Chamber

Martin Obholz, D. Peier

Open publisher page 1 citations

Abstract

Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.

About this research paper

What this paper is about

Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.

Key concepts: Anechoic chamber, Electromagnetic reverberation chamber, Acoustics, Transmission line, Reverberation, Feed line, Electric power transmission, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurements of the Induced Power in a Shape Shifting Transmission Line According to Immunity Tests in Reverberation and Semi Anechoic Chamber — Research Paper | ScholarLens