2014Contact DermatitisRequires access

Screening occupational contact allergy to bisphenol F epoxy resin

Kristiina Aalto‐Korte, Katri Suuronen, Outi Kuuliala, Maj‐Len Henriks‐Eckerman, Riitta Jolanki

Open publisher page 34 citations

Abstract

BACKGROUND: Epoxy resins based on diglycidyl ether of bisphenol F (DGEBF) are widely used as such in applications requiring chemical resistance, and also together with diglycidyl ether of bisphenol A resin (DGEBA-R). Concomitant patch test reactions to DGEBA-R and DGEBF resin (DGEBF-R) are common. Previous studies have yielded conflicting results on the frequency of independent DGEBF-R contact allergies. OBJECTIVES: To report the results of over 11 years of screening with DGEBF-R. METHODS: An in-house test substance of DGEBF-R (Epikote 862) was tested in the baseline patch test series, first at 1% and later at 0.25%. Test files were screened for allergic reactions to DGEBF-R and DGEBA-R, and the clinical records of positively reacting patients were analysed for occupation and exposure. RESULTS: Among 1972 patients, 66 (3.3%) reacted to DGEBF-R and 96 (4.9%) to DGEBA-R. Independent DGEBF-R allergies were seen in 5 patients only, and independent DGEBA-R allergies in 35. Specific exposure to DGEBF-R was found in 26 patients. The main occupational fields were the aircraft industry, the electrical and sports equipment industry, boat building, painting/floor coating, tile setting, and pipe relining. CONCLUSIONS: Independent contact allergies to DGEBF-R were rare, and screening with it was not found to be useful.

About this research paper

What this paper is about

BACKGROUND: Epoxy resins based on diglycidyl ether of bisphenol F (DGEBF) are widely used as such in applications requiring chemical resistance, and also together with diglycidyl ether of bisphenol A resin (DGEBA-R). Concomitant patch test reactions to DGEBA-R and DGEBF resin (DGEBF-R) are common. Previous studies have yielded conflicting results on the frequency of independent DGEBF-R contact allergies. OBJECTIVES: To report the results of over 11 years of screening with DGEBF-R. METHODS: An in-house test substance of DGEBF-R (Epikote 862) was tested in the baseline patch test series, first at 1% and later at 0.25%. Test files were screened for allergic reactions to DGEBF-R and DGEBA-R, and the clinical records of positively reacting patients were analysed for occupation and exposure. RESULTS: Among 1972 patients, 66 (3.3%) reacted to DGEBF-R and 96 (4.9%) to DGEBA-R. Independent DGEBF-R allergies were seen in 5 patients only, and independent DGEBA-R allergies in 35. Specific exposure to DGEBF-R was found in 26 patients. The main occupational fields were the aircraft industry, the electrical and sports equipment industry, boat building, painting/floor coating, tile setting, and pipe relining. CONCLUSIONS: Independent contact allergies to DGEBF-R were rare, and screening with it was not found to be useful.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Epoxy resins based on diglycidyl ether of bisphenol F (DGEBF) are widely used as such in applications requiring chemical resistance, and also together with diglycidyl ether of bisphenol A resin (DGEBA-R). Concomitant patch test reactions to DGEBA-R and DGEBF resin (DGEBF-R) are common. Previous studies have yielded conflicting results on the frequency of independent DGEBF-R contact allergies. OBJECTIVES: To report the results of over 11 years of screening with DGEBF-R. METHODS: An in-house test substance of DGEBF-R (Epikote 862) was tested in the baseline patch test series, first at 1% and later at 0.25%. Test files were screened for allergic reactions to DGEBF-R and DGEBA-R, and the clinical records of positively reacting patients were analysed for occupation and exposure. RESULTS: Among 1972 patients, 66 (3.3%) reacted to DGEBF-R and 96 (4.9%) to DGEBA-R. Independent DGEBF-R allergies were seen in 5 patients only, and independent DGEBA-R allergies in 35. Specific exposure to DGEBF-R was found in 26 patients. The main occupational fields were the aircraft industry, the electrical and sports equipment industry, boat building, painting/floor coating, tile setting, and pipe relining. CONCLUSIONS: Independent contact allergies to DGEBF-R were rare, and screening with it was not found to be useful.

Key concepts: Epoxy, Contact allergy, Diglycidyl ether, Allergy, Patch test, Bisphenol A, Contact dermatitis, Allergic contact dermatitis