1997•Journal of Analytical ToxicologyOpen access

The Stability of Ethanol in Human Whole Blood Controls: An Interlaboratory Evaluation

Kurt M. Dubowski, Richard H. Gadsden, A. Poklis

Open full text 29 citations

Abstract

Sterile whole human blood control materials were commercially prepared in batches containing anticoagulants and preservatives and approximately 90, 150, and 230 mg/dL ethanol with and without 0.3% (w/v) sodium azide. Aliquots in sealed vials were stored by the manufacturer at 2-8 degrees C until shipped monthly to three academic toxicology laboratories that analyzed them in duplicate by gas chromatographic headspace methods at monthly intervals for one year. The resulting data were pooled, and grand mean values were statistically analyzed to determine the respective alcohol stability in these azide-free and azide-containing blood samples. Azide-containing blood samples showed no alcohol losses during the 1-year period. Azide-free blood containing 1.0% (w/v) sodium fluoride and anticoagulants had small alcohol decreases over time, the total losses after one year being less than 5% of the original alcohol concentrations. The initial alcohol concentration of approximately 40 mg/dL also did not change during storage of additional samples of azide-free blood for one month at 4 degrees C. We concluded that addition of sodium azide to performance-test and control blood specimens for alcohol analysis is unnecessary and unwarranted and that alcohol losses in such blood samples can be minimized by simple appropriate treatments and conditions.

Open-access reader

About this research paper

What this paper is about

Sterile whole human blood control materials were commercially prepared in batches containing anticoagulants and preservatives and approximately 90, 150, and 230 mg/dL ethanol with and without 0.3% (w/v) sodium azide. Aliquots in sealed vials were stored by the manufacturer at 2-8 degrees C until shipped monthly to three academic toxicology laboratories that analyzed them in duplicate by gas chromatographic headspace methods at monthly intervals for one year. The resulting data were pooled, and grand mean values were statistically analyzed to determine the respective alcohol stability in these azide-free and azide-containing blood samples. Azide-containing blood samples showed no alcohol losses during the 1-year period. Azide-free blood containing 1.0% (w/v) sodium fluoride and anticoagulants had small alcohol decreases over time, the total losses after one year being less than 5% of the original alcohol concentrations. The initial alcohol concentration of approximately 40 mg/dL also did not change during storage of additional samples of azide-free blood for one month at 4 degrees C. We concluded that addition of sodium azide to performance-test and control blood specimens for alcohol analysis is unnecessary and unwarranted and that alcohol losses in such blood samples can be minimized by simple appropriate treatments and conditions.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sterile whole human blood control materials were commercially prepared in batches containing anticoagulants and preservatives and approximately 90, 150, and 230 mg/dL ethanol with and without 0.3% (w/v) sodium azide. Aliquots in sealed vials were stored by the manufacturer at 2-8 degrees C until shipped monthly to three academic toxicology laboratories that analyzed them in duplicate by gas chromatographic headspace methods at monthly intervals for one year. The resulting data were pooled, and grand mean values were statistically analyzed to determine the respective alcohol stability in these azide-free and azide-containing blood samples. Azide-containing blood samples showed no alcohol losses during the 1-year period. Azide-free blood containing 1.0% (w/v) sodium fluoride and anticoagulants had small alcohol decreases over time, the total losses after one year being less than 5% of the original alcohol concentrations. The initial alcohol concentration of approximately 40 mg/dL also did not change during storage of additional samples of azide-free blood for one month at 4 degrees C. We concluded that addition of sodium azide to performance-test and control blood specimens for alcohol analysis is unnecessary and unwarranted and that alcohol losses in such blood samples can be minimized by simple appropriate treatments and conditions.

Key concepts: Sodium azide, Alcohol, Azide, Chemistry, Ethanol, Chromatography, Preservative, Whole blood

Related papers

Back to paper searchBrowse research topicsOriginal source
The Stability of Ethanol in Human Whole Blood Controls: An Interlaboratory Evaluation — Research Paper | ScholarLens