2010UTS ePRESS (University of Technology Sydney)Requires access

A novel control strategy for Doubly Fed Induction Generator and Permanent Magnet Synchronous Generator during voltage dips

Jiefeng Hu, Jianguo Zhu, David G. Dorrell, Yi Wang, Yongchang Zhang, Wei Xu, Yongjian Li

Open publisher page 5 citations

Abstract

This paper proposes a novel control strategy for Doubly Fed Induction Generator (DFIG) based wind power system and Permanent Magnet Synchronous Generator (PMSG) based wind power system during grid voltage dips. Based on a comparative study, the rotor over-current of DFIG and DC-link over-voltage of PMSG are identified as two main issues during grid voltage dips. A novel control strategy is proposed to enhance the wind farm Fault Ride Through (FRT) capability to some degree without additional devices, taking both grid code requirements and wind turbine requirements into account. A wind farm model consisting of DFIGs and PMSGs is built up. The effectiveness of the solution is demonstrated after simulation using MATLAB/SIMULINK.

About this research paper

What this paper is about

This paper proposes a novel control strategy for Doubly Fed Induction Generator (DFIG) based wind power system and Permanent Magnet Synchronous Generator (PMSG) based wind power system during grid voltage dips. Based on a comparative study, the rotor over-current of DFIG and DC-link over-voltage of PMSG are identified as two main issues during grid voltage dips. A novel control strategy is proposed to enhance the wind farm Fault Ride Through (FRT) capability to some degree without additional devices, taking both grid code requirements and wind turbine requirements into account. A wind farm model consisting of DFIGs and PMSGs is built up. The effectiveness of the solution is demonstrated after simulation using MATLAB/SIMULINK.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper proposes a novel control strategy for Doubly Fed Induction Generator (DFIG) based wind power system and Permanent Magnet Synchronous Generator (PMSG) based wind power system during grid voltage dips. Based on a comparative study, the rotor over-current of DFIG and DC-link over-voltage of PMSG are identified as two main issues during grid voltage dips. A novel control strategy is proposed to enhance the wind farm Fault Ride Through (FRT) capability to some degree without additional devices, taking both grid code requirements and wind turbine requirements into account. A wind farm model consisting of DFIGs and PMSGs is built up. The effectiveness of the solution is demonstrated after simulation using MATLAB/SIMULINK.

Key concepts: Grid code, Permanent magnet synchronous generator, Induction generator, Wind power, Rotor (electric), Fault (geology), Low voltage ride through, Control theory (sociology)

Related papers

Back to paper searchBrowse research topicsOriginal source
A novel control strategy for Doubly Fed Induction Generator and Permanent Magnet Synchronous Generator during voltage dips — Research Paper | ScholarLens