2015NeurophotonicsOpen access

Fluorescence micro-optical sectioning tomography using acousto-optical deflector-based confocal scheme

Xiaoli Qi, Tao Yang, Longhui Li, Jiancun Wang, Shaoqun Zeng, Xiaohua Lv

Open full text 13 citations

Abstract

Fluorescent labeling has opened up the possibility of clarifying the complex distribution and circuit wiring of specific neural circuits for particular functions. To acquire the brain-wide fluorescently labeled neural wiring, we have previously developed the fluorescence micro-optical sectioning tomography imaging system. This employs simultaneous mechanical sectioning and confocal imaging of the slices, and is capable of acquiring the image dataset of a centimeter-sized whole-mouse brain at a voxel resolution of [Formula: see text]. We analyze the key optical considerations for the use of an acousto-optical deflector (AOD) scanner-based confocal detection scheme in this system. As a result, the influence of confocal detection, the imaging site during sectioning, and AOD fast scan mode on signal-to-background noise ratio are described. It is shown that mechanical sectioning to separate the slice and optical sectioning by confocal detection should be combined to maximize background suppression in simultaneous fast scan imaging while sectioning system setup.

Open-access reader

About this research paper

What this paper is about

Fluorescent labeling has opened up the possibility of clarifying the complex distribution and circuit wiring of specific neural circuits for particular functions. To acquire the brain-wide fluorescently labeled neural wiring, we have previously developed the fluorescence micro-optical sectioning tomography imaging system. This employs simultaneous mechanical sectioning and confocal imaging of the slices, and is capable of acquiring the image dataset of a centimeter-sized whole-mouse brain at a voxel resolution of [Formula: see text]. We analyze the key optical considerations for the use of an acousto-optical deflector (AOD) scanner-based confocal detection scheme in this system. As a result, the influence of confocal detection, the imaging site during sectioning, and AOD fast scan mode on signal-to-background noise ratio are described. It is shown that mechanical sectioning to separate the slice and optical sectioning by confocal detection should be combined to maximize background suppression in simultaneous fast scan imaging while sectioning system setup.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fluorescent labeling has opened up the possibility of clarifying the complex distribution and circuit wiring of specific neural circuits for particular functions. To acquire the brain-wide fluorescently labeled neural wiring, we have previously developed the fluorescence micro-optical sectioning tomography imaging system. This employs simultaneous mechanical sectioning and confocal imaging of the slices, and is capable of acquiring the image dataset of a centimeter-sized whole-mouse brain at a voxel resolution of [Formula: see text]. We analyze the key optical considerations for the use of an acousto-optical deflector (AOD) scanner-based confocal detection scheme in this system. As a result, the influence of confocal detection, the imaging site during sectioning, and AOD fast scan mode on signal-to-background noise ratio are described. It is shown that mechanical sectioning to separate the slice and optical sectioning by confocal detection should be combined to maximize background suppression in simultaneous fast scan imaging while sectioning system setup.

Key concepts: Optical sectioning, Confocal, Confocal microscopy, Materials science, Fluorescence, Optics, Fluorescence-lifetime imaging microscopy, Tomography

Related papers

Back to paper searchBrowse research topicsOriginal source
Fluorescence micro-optical sectioning tomography using acousto-optical deflector-based confocal scheme — Research Paper | ScholarLens