Fluorescence micro-optical sectioning tomography using acousto-optical deflector-based confocal scheme
Xiaoli Qi, Tao Yang, Longhui Li, Jiancun Wang, Shaoqun Zeng, Xiaohua Lv
Abstract
Open-access reader
Xiaoli Qi, Tao Yang, Longhui Li, Jiancun Wang, Shaoqun Zeng, Xiaohua Lv
Abstract
Open-access reader
Fluorescent labeling has opened up the possibility of clarifying the complex distribution and circuit wiring of specific neural circuits for particular functions. To acquire the brain-wide fluorescently labeled neural wiring, we have previously developed the fluorescence micro-optical sectioning tomography imaging system. This employs simultaneous mechanical sectioning and confocal imaging of the slices, and is capable of acquiring the image dataset of a centimeter-sized whole-mouse brain at a voxel resolution of [Formula: see text]. We analyze the key optical considerations for the use of an acousto-optical deflector (AOD) scanner-based confocal detection scheme in this system. As a result, the influence of confocal detection, the imaging site during sectioning, and AOD fast scan mode on signal-to-background noise ratio are described. It is shown that mechanical sectioning to separate the slice and optical sectioning by confocal detection should be combined to maximize background suppression in simultaneous fast scan imaging while sectioning system setup.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Fluorescent labeling has opened up the possibility of clarifying the complex distribution and circuit wiring of specific neural circuits for particular functions. To acquire the brain-wide fluorescently labeled neural wiring, we have previously developed the fluorescence micro-optical sectioning tomography imaging system. This employs simultaneous mechanical sectioning and confocal imaging of the slices, and is capable of acquiring the image dataset of a centimeter-sized whole-mouse brain at a voxel resolution of [Formula: see text]. We analyze the key optical considerations for the use of an acousto-optical deflector (AOD) scanner-based confocal detection scheme in this system. As a result, the influence of confocal detection, the imaging site during sectioning, and AOD fast scan mode on signal-to-background noise ratio are described. It is shown that mechanical sectioning to separate the slice and optical sectioning by confocal detection should be combined to maximize background suppression in simultaneous fast scan imaging while sectioning system setup.
Key concepts: Optical sectioning, Confocal, Confocal microscopy, Materials science, Fluorescence, Optics, Fluorescence-lifetime imaging microscopy, Tomography