Methods for the calibrated measurement of the scattering parameters of planar multi-port devices
Ilona Rolfes, Burkhard Schiek
Abstract
Open-access reader
Ilona Rolfes, Burkhard Schiek
Abstract
Open-access reader
Abstract. In this article, the error-corrected determination of complex scattering parameters of multi-port devices by means of a 2-port vector network analyzer is presented. As only two ports of the device under test can be connected to the analyzer ports at a time, the remaining device ports have to be terminated by external reflections. In order to measure the scattering parameters of the DUT without the influence of systematic errors and of the external terminations, an error correction has to be performed besides the calibration. For this purpose, the application of the multi-port procedure is presented. This method has the advantage, that the external reflective terminations can be chosen arbitrarily. Furthermore, these terminations can be unknown except for one. An automatized measurement system based on a switching network is shown, which is optimized for the measurement of planar microwave circuits. An error model for the description of the measurement setup as well as a calibration procedure for the elimination of the systematic errors are presented.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract. In this article, the error-corrected determination of complex scattering parameters of multi-port devices by means of a 2-port vector network analyzer is presented. As only two ports of the device under test can be connected to the analyzer ports at a time, the remaining device ports have to be terminated by external reflections. In order to measure the scattering parameters of the DUT without the influence of systematic errors and of the external terminations, an error correction has to be performed besides the calibration. For this purpose, the application of the multi-port procedure is presented. This method has the advantage, that the external reflective terminations can be chosen arbitrarily. Furthermore, these terminations can be unknown except for one. An automatized measurement system based on a switching network is shown, which is optimized for the measurement of planar microwave circuits. An error model for the description of the measurement setup as well as a calibration procedure for the elimination of the systematic errors are presented.
Key concepts: Scattering parameters, Device under test, Calibration, Planar, Port (circuit theory), Network analyzer (electrical), Microwave, Computer science