2004•Critical Care MedicineRequires access

Vasopressor and inotropic support in septic shock: An evidence-based review

Richard J Beale, Steven M. Hollenberg, Jean‐Louis Vincent, Joseph E. Parrillo

Open publisher page 261 citations

Abstract

OBJECTIVE: In 2003, critical care and infectious disease experts representing 11 international organizations developed management guidelines for vasopressor and inotropic support in septic shock that would be of practical use for the bedside clinician, under the auspices of the Surviving Sepsis Campaign, an international effort to increase awareness and to improve outcome in severe sepsis. DESIGN: The process included a modified Delphi method, a consensus conference, several subsequent smaller meetings of subgroups and key individuals, teleconferences, and electronic-based discussion among subgroups and among the entire committee. METHODS: The modified Delphi methodology used for grading recommendations built on a 2001 publication sponsored by the International Sepsis Forum. We undertook a systematic review of the literature graded along five levels to create recommendation grades from A to E, with A being the highest grade. Pediatric considerations to contrast adult and pediatric management are in the article by Parker et al. on p. S591. CONCLUSION: An arterial catheter should be placed as soon as possible in patients with septic shock. Vasopressors are indicated to maintain mean arterial pressure of <65 mm Hg, both during and following adequate fluid resuscitation. Norepinephrine or dopamine are the vasopressors of choice in the treatment of septic shock. Norepinephrine may be combined with dobutamine when cardiac output is being measured. Epinephrine, phenylephrine, and vasopressin are not recommended as first-line agents in the treatment of septic shock. Vasopressin may be considered for salvage therapy. Low-dose dopamine is not recommended for the purpose of renal protection. Dobutamine is recommended as the agent of choice to increase cardiac output but should not be used for the purpose of increasing cardiac output above physiologic levels.

About this research paper

What this paper is about

OBJECTIVE: In 2003, critical care and infectious disease experts representing 11 international organizations developed management guidelines for vasopressor and inotropic support in septic shock that would be of practical use for the bedside clinician, under the auspices of the Surviving Sepsis Campaign, an international effort to increase awareness and to improve outcome in severe sepsis. DESIGN: The process included a modified Delphi method, a consensus conference, several subsequent smaller meetings of subgroups and key individuals, teleconferences, and electronic-based discussion among subgroups and among the entire committee. METHODS: The modified Delphi methodology used for grading recommendations built on a 2001 publication sponsored by the International Sepsis Forum. We undertook a systematic review of the literature graded along five levels to create recommendation grades from A to E, with A being the highest grade. Pediatric considerations to contrast adult and pediatric management are in the article by Parker et al. on p. S591. CONCLUSION: An arterial catheter should be placed as soon as possible in patients with septic shock. Vasopressors are indicated to maintain mean arterial pressure of <65 mm Hg, both during and following adequate fluid resuscitation. Norepinephrine or dopamine are the vasopressors of choice in the treatment of septic shock. Norepinephrine may be combined with dobutamine when cardiac output is being measured. Epinephrine, phenylephrine, and vasopressin are not recommended as first-line agents in the treatment of septic shock. Vasopressin may be considered for salvage therapy. Low-dose dopamine is not recommended for the purpose of renal protection. Dobutamine is recommended as the agent of choice to increase cardiac output but should not be used for the purpose of increasing cardiac output above physiologic levels.

Why it matters

OpenAlex reports 261 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: In 2003, critical care and infectious disease experts representing 11 international organizations developed management guidelines for vasopressor and inotropic support in septic shock that would be of practical use for the bedside clinician, under the auspices of the Surviving Sepsis Campaign, an international effort to increase awareness and to improve outcome in severe sepsis. DESIGN: The process included a modified Delphi method, a consensus conference, several subsequent smaller meetings of subgroups and key individuals, teleconferences, and electronic-based discussion among subgroups and among the entire committee. METHODS: The modified Delphi methodology used for grading recommendations built on a 2001 publication sponsored by the International Sepsis Forum. We undertook a systematic review of the literature graded along five levels to create recommendation grades from A to E, with A being the highest grade. Pediatric considerations to contrast adult and pediatric management are in the article by Parker et al. on p. S591. CONCLUSION: An arterial catheter should be placed as soon as possible in patients with septic shock. Vasopressors are indicated to maintain mean arterial pressure of <65 mm Hg, both during and following adequate fluid resuscitation. Norepinephrine or dopamine are the vasopressors of choice in the treatment of septic shock. Norepinephrine may be combined with dobutamine when cardiac output is being measured. Epinephrine, phenylephrine, and vasopressin are not recommended as first-line agents in the treatment of septic shock. Vasopressin may be considered for salvage therapy. Low-dose dopamine is not recommended for the purpose of renal protection. Dobutamine is recommended as the agent of choice to increase cardiac output but should not be used for the purpose of increasing cardiac output above physiologic levels.

Key concepts: Medicine, Dobutamine, Septic shock, Norepinephrine, Surviving Sepsis Campaign, Sepsis, Intensive care medicine, Terlipressin

Related papers

Back to paper searchBrowse research topicsOriginal source
Vasopressor and inotropic support in septic shock: An evidence-based review — Research Paper | ScholarLens