2012•Nephrology Dialysis TransplantationOpen access

Safety and efficacy of local periadventitial delivery of sirolimus for improving hemodialysis graft patency: first human experience with a sirolimus-eluting collagen membrane (Coll-R)

W. D. Paulson, Nodar N Kipshidze, Kote Kipiani, Natalia Beridze, Maria V. DeVita, S. Shenoy, S. S. Iyer

Open full text 71 citations

Abstract

BACKGROUND: Neointimal hyperplasia causes a high rate of hemodialysis synthetic graft failure. Thus, therapies that inhibit neointimal hyperplasia are urgently needed. The Coll-R is a sirolimus-eluting collagen matrix designed for intra-operative perivascular implantation around the graft-venous anastomosis. Sirolimus is an anti-proliferative drug that has proven clinical utility in suppressing neointimal tissue growth in coronary artery disease when delivered locally to the vascular wall by an endovascular drug eluting stent. METHODS: A cohort of 12 chronic hemodialysis patients underwent surgical placement of 13 polytetrafluoroethylene grafts + Coll-R and were followed for up to 24 months. The primary endpoint was safety (freedom from device related adverse events). Secondary endpoints were pharmacokinetics of sirolimus release, success of Coll-R implantation and primary unassisted graft patency. RESULTS: There were no technical failures, infections, vascular anastomotic or wound-healing problems. Whole blood sirolimus levels rose to a mean peak of 4.8 ng/mL at 6 h and fell to <1 ng/mL at 1 week (n = 5). Twelve and 24-month primary unassisted patencies were 76 and 38%, respectively, and the thrombosis rate was 0.37/patient-year. CONCLUSIONS: Perivascular implantation of the Coll-R during graft surgery safely delivered sirolimus to the vascular wall. Systemic sirolimus levels were sub-therapeutic for immunosuppression. This small first-in-human study supports the concept that the Coll-R can safely deliver sirolimus to the graft-venous anastomosis. Safety and patency in this small study were sufficiently encouraging to justify randomized controlled trials to further test the efficacy of the Coll-R.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Neointimal hyperplasia causes a high rate of hemodialysis synthetic graft failure. Thus, therapies that inhibit neointimal hyperplasia are urgently needed. The Coll-R is a sirolimus-eluting collagen matrix designed for intra-operative perivascular implantation around the graft-venous anastomosis. Sirolimus is an anti-proliferative drug that has proven clinical utility in suppressing neointimal tissue growth in coronary artery disease when delivered locally to the vascular wall by an endovascular drug eluting stent. METHODS: A cohort of 12 chronic hemodialysis patients underwent surgical placement of 13 polytetrafluoroethylene grafts + Coll-R and were followed for up to 24 months. The primary endpoint was safety (freedom from device related adverse events). Secondary endpoints were pharmacokinetics of sirolimus release, success of Coll-R implantation and primary unassisted graft patency. RESULTS: There were no technical failures, infections, vascular anastomotic or wound-healing problems. Whole blood sirolimus levels rose to a mean peak of 4.8 ng/mL at 6 h and fell to <1 ng/mL at 1 week (n = 5). Twelve and 24-month primary unassisted patencies were 76 and 38%, respectively, and the thrombosis rate was 0.37/patient-year. CONCLUSIONS: Perivascular implantation of the Coll-R during graft surgery safely delivered sirolimus to the vascular wall. Systemic sirolimus levels were sub-therapeutic for immunosuppression. This small first-in-human study supports the concept that the Coll-R can safely deliver sirolimus to the graft-venous anastomosis. Safety and patency in this small study were sufficiently encouraging to justify randomized controlled trials to further test the efficacy of the Coll-R.

Why it matters

OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Neointimal hyperplasia causes a high rate of hemodialysis synthetic graft failure. Thus, therapies that inhibit neointimal hyperplasia are urgently needed. The Coll-R is a sirolimus-eluting collagen matrix designed for intra-operative perivascular implantation around the graft-venous anastomosis. Sirolimus is an anti-proliferative drug that has proven clinical utility in suppressing neointimal tissue growth in coronary artery disease when delivered locally to the vascular wall by an endovascular drug eluting stent. METHODS: A cohort of 12 chronic hemodialysis patients underwent surgical placement of 13 polytetrafluoroethylene grafts + Coll-R and were followed for up to 24 months. The primary endpoint was safety (freedom from device related adverse events). Secondary endpoints were pharmacokinetics of sirolimus release, success of Coll-R implantation and primary unassisted graft patency. RESULTS: There were no technical failures, infections, vascular anastomotic or wound-healing problems. Whole blood sirolimus levels rose to a mean peak of 4.8 ng/mL at 6 h and fell to <1 ng/mL at 1 week (n = 5). Twelve and 24-month primary unassisted patencies were 76 and 38%, respectively, and the thrombosis rate was 0.37/patient-year. CONCLUSIONS: Perivascular implantation of the Coll-R during graft surgery safely delivered sirolimus to the vascular wall. Systemic sirolimus levels were sub-therapeutic for immunosuppression. This small first-in-human study supports the concept that the Coll-R can safely deliver sirolimus to the graft-venous anastomosis. Safety and patency in this small study were sufficiently encouraging to justify randomized controlled trials to further test the efficacy of the Coll-R.

Key concepts: Medicine, Sirolimus, Neointimal hyperplasia, Hemodialysis, Stent, Intimal hyperplasia, Urology, Coronary artery disease

Related papers

Back to paper searchBrowse research topicsOriginal source
Safety and efficacy of local periadventitial delivery of sirolimus for improving hemodialysis graft patency: first human experience with a sirolimus-eluting collagen membrane (Coll-R) — Research Paper | ScholarLens