Abstract
Kaï Hassler, Marcel Leutenegger, Per Rigler, Ramachandra Rao, Rudolf W. Rigler, Michael Gösch, Theo Lasser
Abstract
We designed a fluorescence correlation spectroscopy (FCS) system for measurements on surfaces. The system consists of an objective-type total internal reflection fluorescence (TIRF) microscopy setup, adapted to measure FCS. Here, the fluorescence exciting evanescent wave is generated by epi-illumination through the periphery of a high NA oil-immersion objective. The main advantages with respect to conventional FCS systems are an improvement in terms of counts per molecule (cpm) and a high signal to background ratio. This is demonstrated by investigating diffusion as well as binding and release of single molecules on a glass surface. Furthermore, the size and shape of the molecule detection efficiency (MDE) function was calculated, using a wave-vectorial approach and taking into account the influence of the dielectric interface on the emission properties of fluorophores.
OpenAlex reports 74 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We designed a fluorescence correlation spectroscopy (FCS) system for measurements on surfaces. The system consists of an objective-type total internal reflection fluorescence (TIRF) microscopy setup, adapted to measure FCS. Here, the fluorescence exciting evanescent wave is generated by epi-illumination through the periphery of a high NA oil-immersion objective. The main advantages with respect to conventional FCS systems are an improvement in terms of counts per molecule (cpm) and a high signal to background ratio. This is demonstrated by investigating diffusion as well as binding and release of single molecules on a glass surface. Furthermore, the size and shape of the molecule detection efficiency (MDE) function was calculated, using a wave-vectorial approach and taking into account the influence of the dielectric interface on the emission properties of fluorophores.