Recovery of Cholesterol and Triacylglycerol in Very-Fast Ultracentrifugation of Human Lipoproteins in a Large Range of Concentrations
W. Leonhardt, Jens Pietzsch, Ulrich Julius, M Hanefeld
Abstract
Open-access reader
W. Leonhardt, Jens Pietzsch, Ulrich Julius, M Hanefeld
Abstract
Open-access reader
Very-fast ultracentrifugation using a benchtop ultracentrifuge was applied to the analysis of lipoproteins in 0.5 ml of human plasma. VLDL, IDL and LDL were flotated at densities of 1.006, 1.019 and 1.063 kg/l in runs lasting 30, 100 and 100 minutes. Chylomicrons, if present, were flotated in a separate run. HDL were isolated by precipitation of the apolipoprotein B-containing lipoproteins from total plasma using polyethylene glycol. Three series of separations were routinely performed: 1. VLDL run alone (632 samples), 2. VLDL run + LDL run (122 samples), and 3. Chylomicron separation + VLDL run + IDL run (92 samples). The concentrations of cholesterol and triacylglycerol were obtained for plasma, chylomicrons, VLDL, IDL, LDL and HDL. Plasma values ranged from 1.8 to 37.1 mmol/l cholesterol and 0.26 to 50.2 mmol/l triacylglycerol. The plasma triacylglycerol concentrations were corrected for free glycerol by 3% (for triacylglycerols < 2.5 mmol/l) and by 2% (for triacylglycerols > or = 2.5 mmol/l). The recovery rate of lipids after ultracentrifugation was determined by comparing the concentrations in lipoproteins and in plasma. It was near to 100% and decreased for samples with extremely high lipid concentrations.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Very-fast ultracentrifugation using a benchtop ultracentrifuge was applied to the analysis of lipoproteins in 0.5 ml of human plasma. VLDL, IDL and LDL were flotated at densities of 1.006, 1.019 and 1.063 kg/l in runs lasting 30, 100 and 100 minutes. Chylomicrons, if present, were flotated in a separate run. HDL were isolated by precipitation of the apolipoprotein B-containing lipoproteins from total plasma using polyethylene glycol. Three series of separations were routinely performed: 1. VLDL run alone (632 samples), 2. VLDL run + LDL run (122 samples), and 3. Chylomicron separation + VLDL run + IDL run (92 samples). The concentrations of cholesterol and triacylglycerol were obtained for plasma, chylomicrons, VLDL, IDL, LDL and HDL. Plasma values ranged from 1.8 to 37.1 mmol/l cholesterol and 0.26 to 50.2 mmol/l triacylglycerol. The plasma triacylglycerol concentrations were corrected for free glycerol by 3% (for triacylglycerols < 2.5 mmol/l) and by 2% (for triacylglycerols > or = 2.5 mmol/l). The recovery rate of lipids after ultracentrifugation was determined by comparing the concentrations in lipoproteins and in plasma. It was near to 100% and decreased for samples with extremely high lipid concentrations.
Key concepts: Chylomicron, Very low-density lipoprotein, Ultracentrifuge, Chemistry, Chromatography, Intermediate-density lipoprotein, Cholesterol, Lipoprotein