2001•European Respiratory JournalOpen access

Plethysmographic measurements of lung volume and airway resistance

Janet Stocks, S. Godfrey, Caroline Beardsmore, Ephraim Bar‐Yishay, Robert G. Castile

Open full text 198 citations

Abstract

Functional residual capacity (FRC) is the only static lung volume that can be measured routinely in infants. It is important for interpreting volume-dependent pulmonary mechanics such as airway resistance or forced expiratory flows, and for defining normal lung growth. Despite requiring complex equipment, the plethysmographic method for measuring FRC is very simple to apply and, unlike the gas dilution techniques, enables repeat measures of lung volume to be obtained within a few minutes. This method has the further advantage that with suitable adaptations to the equipment, simultaneous measurements of airway resistance can also be obtained. The aim of this paper is to provide recommendations pertaining to equipment requirements, study procedures and reporting of data for plethysmographic measurements in infants. Implementation of these recommendations should help to ensure that such measurements are as accurate as possible and that meaningful comparisons can be made between data collected in different centres or with different equipment. These guidelines cover numerous aspects including terminology and definitions, equipment, data acquisition and analysis and reporting of results and also highlight areas where further research is needed before consensus can be reached.

Open-access reader

About this research paper

What this paper is about

Functional residual capacity (FRC) is the only static lung volume that can be measured routinely in infants. It is important for interpreting volume-dependent pulmonary mechanics such as airway resistance or forced expiratory flows, and for defining normal lung growth. Despite requiring complex equipment, the plethysmographic method for measuring FRC is very simple to apply and, unlike the gas dilution techniques, enables repeat measures of lung volume to be obtained within a few minutes. This method has the further advantage that with suitable adaptations to the equipment, simultaneous measurements of airway resistance can also be obtained. The aim of this paper is to provide recommendations pertaining to equipment requirements, study procedures and reporting of data for plethysmographic measurements in infants. Implementation of these recommendations should help to ensure that such measurements are as accurate as possible and that meaningful comparisons can be made between data collected in different centres or with different equipment. These guidelines cover numerous aspects including terminology and definitions, equipment, data acquisition and analysis and reporting of results and also highlight areas where further research is needed before consensus can be reached.

Why it matters

OpenAlex reports 198 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Functional residual capacity (FRC) is the only static lung volume that can be measured routinely in infants. It is important for interpreting volume-dependent pulmonary mechanics such as airway resistance or forced expiratory flows, and for defining normal lung growth. Despite requiring complex equipment, the plethysmographic method for measuring FRC is very simple to apply and, unlike the gas dilution techniques, enables repeat measures of lung volume to be obtained within a few minutes. This method has the further advantage that with suitable adaptations to the equipment, simultaneous measurements of airway resistance can also be obtained. The aim of this paper is to provide recommendations pertaining to equipment requirements, study procedures and reporting of data for plethysmographic measurements in infants. Implementation of these recommendations should help to ensure that such measurements are as accurate as possible and that meaningful comparisons can be made between data collected in different centres or with different equipment. These guidelines cover numerous aspects including terminology and definitions, equipment, data acquisition and analysis and reporting of results and also highlight areas where further research is needed before consensus can be reached.

Key concepts: Plethysmograph, Airway resistance, Lung volumes, Functional residual capacity, Volume (thermodynamics), Airway, Terminology, Residual volume

Related papers

Back to paper searchBrowse research topicsOriginal source
Plethysmographic measurements of lung volume and airway resistance — Research Paper | ScholarLens