1956Okayama University Scientific Achievement Repository (Okayama University)Open access

A Simplified Hot-Plate Apparatus for Evaluation of Analgesic Effect

Kazumasa Sanuki, Hiroyuki Ohno

Open full text 3 citations

Abstract

1. A. simple hot-plate apparatus, with comparatively good accuracy in the control of temperature, chiefly composed of a circular lead plate embedded with nicrome-wire heater was devised in order to improve the complications and inconveniences of the hot-plate apparatus used to date in algesimetric determination with mice. 2. The reaction times measured with this hot-plate maintained at 55°C with 500 normal mice showed an average of 9.96 ± 1.58 seconds and about 90% of the total mice exhibited reaction time of 7-13 seconds. With animals showing reaction time within this range, the daily mean reaction time did not vary with measurement once a day for consecutive days and the effect of drugs with comparatively weak analgesic effect was well reproduced with small number examples, such as 12 mice to a group.

About this research paper

What this paper is about

1. A. simple hot-plate apparatus, with comparatively good accuracy in the control of temperature, chiefly composed of a circular lead plate embedded with nicrome-wire heater was devised in order to improve the complications and inconveniences of the hot-plate apparatus used to date in algesimetric determination with mice. 2. The reaction times measured with this hot-plate maintained at 55°C with 500 normal mice showed an average of 9.96 ± 1.58 seconds and about 90% of the total mice exhibited reaction time of 7-13 seconds. With animals showing reaction time within this range, the daily mean reaction time did not vary with measurement once a day for consecutive days and the effect of drugs with comparatively weak analgesic effect was well reproduced with small number examples, such as 12 mice to a group.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

1. A. simple hot-plate apparatus, with comparatively good accuracy in the control of temperature, chiefly composed of a circular lead plate embedded with nicrome-wire heater was devised in order to improve the complications and inconveniences of the hot-plate apparatus used to date in algesimetric determination with mice. 2. The reaction times measured with this hot-plate maintained at 55°C with 500 normal mice showed an average of 9.96 ± 1.58 seconds and about 90% of the total mice exhibited reaction time of 7-13 seconds. With animals showing reaction time within this range, the daily mean reaction time did not vary with measurement once a day for consecutive days and the effect of drugs with comparatively weak analgesic effect was well reproduced with small number examples, such as 12 mice to a group.

Key concepts: Hot plate, Analgesic, Biomedical engineering, Materials science, Mathematics, Chemistry, Surgery, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
A Simplified Hot-Plate Apparatus for Evaluation of Analgesic Effect — Research Paper | ScholarLens