Semi-Preparative Enantiomeric Separation of Ofloxacin by HPLC
Z. Fang, Zhao‐Xia Guo, Qiang Qin, Jun Yan Fan, Y. Yin, Wenbin Zhang
Abstract
Z. Fang, Zhao‐Xia Guo, Qiang Qin, Jun Yan Fan, Y. Yin, Wenbin Zhang
Abstract
A direct semi-preparative high performance liquid chromatography (HPLC) enantioseparation of ofloxacin was performed on chemically immobilized cyclodextrin derivative-mono (6A-azido-6A-deoxy)-per(p-chlorophenyl carbamoylated) β-CD chiral stationary phase. Conditions for semi-preparative separations were established using a 250 × 4.6 mm i.d. column and subsequently extended to a 250 × 10.0 mm i.d. column that enabled separations on a milligram scale. Optimization of the chromatographic conditions (mobile phase and column load) with respect to better efficiency, resolution and peak retention resulted in a system capable of separating up to 304 mg of (-)-(S)-ofloxacin and 56 mg of (+)-(R)-ofloxacin of the racemate over 6 h. The purities of the separated enantiomers were determined by HPLC. Moreover, both separated enantiomers were characterized by mass spectrometry; then, the absolute configuration of the products was clearly confirmed by polarimetry.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A direct semi-preparative high performance liquid chromatography (HPLC) enantioseparation of ofloxacin was performed on chemically immobilized cyclodextrin derivative-mono (6A-azido-6A-deoxy)-per(p-chlorophenyl carbamoylated) β-CD chiral stationary phase. Conditions for semi-preparative separations were established using a 250 × 4.6 mm i.d. column and subsequently extended to a 250 × 10.0 mm i.d. column that enabled separations on a milligram scale. Optimization of the chromatographic conditions (mobile phase and column load) with respect to better efficiency, resolution and peak retention resulted in a system capable of separating up to 304 mg of (-)-(S)-ofloxacin and 56 mg of (+)-(R)-ofloxacin of the racemate over 6 h. The purities of the separated enantiomers were determined by HPLC. Moreover, both separated enantiomers were characterized by mass spectrometry; then, the absolute configuration of the products was clearly confirmed by polarimetry.
Key concepts: Chemistry, Chromatography, Enantiomer, High-performance liquid chromatography, Resolution (logic), Cyclodextrin, Chiral column chromatography, Ofloxacin