2002•Unpublished venueRequires access

Intermittence detection in fretting corrosion studies of electrical contacts

Steven R. Murrell, S. L. McCarthy

Open publisher page 46 citations

Abstract

The occurrence of intermittences in electrical circuits can result in serious reliability problems particularly where low signal voltages and currents are used. It is well known that differential thermal expansion or vibration in electrical connectors can result in micromotion resulting in fretting corrosion. This can lead to an increase in contact resistance and eventual loss of electrical contact. The occurrence of electrical intermittences has been considered a precursor to contact failure associated with fretting corrosion and can cause disruption in digital circuit signals. We report the development of instrumentation that simultaneously measures the occurrence of electrical intermittences along with contact resistance during the fretting of electrical contacts. In addition, the measurement system records contact friction and normal force dynamically. Intermittences can be counted and timed with durations from 20 ns to milliseconds as a function of fretting cycles and correlated with the increase in contact resistance. All systems are integrated under LABVIEW computer control software. Measurements were made on Cu-Cu and Sn-Sn rider/flat combinations. Results will be interpreted in terms of the influence of wear debris on the electrical properties of the contacts.

About this research paper

What this paper is about

The occurrence of intermittences in electrical circuits can result in serious reliability problems particularly where low signal voltages and currents are used. It is well known that differential thermal expansion or vibration in electrical connectors can result in micromotion resulting in fretting corrosion. This can lead to an increase in contact resistance and eventual loss of electrical contact. The occurrence of electrical intermittences has been considered a precursor to contact failure associated with fretting corrosion and can cause disruption in digital circuit signals. We report the development of instrumentation that simultaneously measures the occurrence of electrical intermittences along with contact resistance during the fretting of electrical contacts. In addition, the measurement system records contact friction and normal force dynamically. Intermittences can be counted and timed with durations from 20 ns to milliseconds as a function of fretting cycles and correlated with the increase in contact resistance. All systems are integrated under LABVIEW computer control software. Measurements were made on Cu-Cu and Sn-Sn rider/flat combinations. Results will be interpreted in terms of the influence of wear debris on the electrical properties of the contacts.

Why it matters

OpenAlex reports 46 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The occurrence of intermittences in electrical circuits can result in serious reliability problems particularly where low signal voltages and currents are used. It is well known that differential thermal expansion or vibration in electrical connectors can result in micromotion resulting in fretting corrosion. This can lead to an increase in contact resistance and eventual loss of electrical contact. The occurrence of electrical intermittences has been considered a precursor to contact failure associated with fretting corrosion and can cause disruption in digital circuit signals. We report the development of instrumentation that simultaneously measures the occurrence of electrical intermittences along with contact resistance during the fretting of electrical contacts. In addition, the measurement system records contact friction and normal force dynamically. Intermittences can be counted and timed with durations from 20 ns to milliseconds as a function of fretting cycles and correlated with the increase in contact resistance. All systems are integrated under LABVIEW computer control software. Measurements were made on Cu-Cu and Sn-Sn rider/flat combinations. Results will be interpreted in terms of the influence of wear debris on the electrical properties of the contacts.

Key concepts: Fretting, Electrical contacts, Materials science, Contact resistance, Electrical resistance and conductance, Corrosion, SIGNAL (programming language), Voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Intermittence detection in fretting corrosion studies of electrical contacts — Research Paper | ScholarLens